OKLAHOMA CITY, OK —
OSHA Inspection: CARGILL HEAT TREAT, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CARGILL HEAT TREAT, LLC in 1626 S.E. 40TH, OKLAHOMA CITY, OK 73129 (NAICS 332811). OSHA activity number 343649133.
Where did this inspection happen?
- Establishment
- CARGILL HEAT TREAT, LLC
- Site address
- 1626 S.E. 40TH
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73129
- Mailing
- 1626 S.E. 40TH, OKLAHOMA CITY, OK 73129
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332811
- Employees
- 26
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.111 C07
- Issued
- Abate by
- Penalty
- Initial $6630.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.111(c)(7): The employer did not protect ammonia systems from vehicle damage. On or about December 10, 2018 and at times prior thereto, employees were exposed to storage tanks of anhydrous ammonia that were not protected from vehicular traffic. Employees were exposed to fire /explosion and chemical hazards.
Recent events (2)
- — I (S) $2000
- — Z (S) $6630
1910.124 G02
- Issued
- Abate by
- Penalty
- Initial $6630.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.124(g)(2): Employees who worked with liquids that could burn, irritate, or otherwise harm their skin were not provided with an emergency shower and eye-wash station close to the dipping and coating operation. :Note: In place of this equipment, the employee may use a water hose that is at least 4 feet (1.22 m) long and at least 3/4 of an inch (18 mm) thick with a quick-opening valve and carrying a pressure of 25 pounds per square inch (1.62 k/cm2) or less. On or about December 10, 2018 and at times prior thereto, employees were not provided an emergency shower and eyewash station while working with corrosive chemicals such as, but not limited to anhydrous ammonia, sand blast media, degreaser wash solution.
Recent events (2)
- — I (S) $2000
- — Z (S) $6630
1910.147 A03 I
- Issued
- Abate by
- Penalty
- Initial $6630.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.147(a)(3)(i): Employer failed to establish a program and utilize procedures for affixing appropriate lockout devices or tagout devices to energy isolating devices, and to otherwise disable machines or equipment to prevent unexpected energization, start up or release of stored energy in order to prevent injury to employees. On or about December 10, 2018 and at times prior thereto, the employer did not establish and utilize an energy control program and procedures to ensure machines are disabled and cannot unexpectedly startup. Employees were exposed to hazards including fire/explosion and chemical exposure.
Recent events (2)
- — I (S) $2000
- — Z (S) $6630
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $5304.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). On or about December 10, 2018 and at times prior thereto, the employer did not ensure that employees operating powered industrial trucks received training. This exposed employees to struck by and crushed by hazards.
Recent events (2)
- — I (S) $2000
- — Z (S) $5304
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $5304.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment On or about December 10, 2018 and at times prior thereto, the employer did not ensure that the blanks and covers were installed on electrical panels in the SW and NE corners of the West shop bldg. This exposed employees to electrical shock hazards.
Recent events (2)
- — I (S) $2000
- — Z (S) $5304
1910.1200 E01 II
- Issued
- Abate by
- Penalty
- Initial $6630.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1)(ii): The written hazard communication program did not include the methods the employer would use to inform employees of the hazards of non-routine tasks, and the hazards associated with chemicals contained in unlabeled pipes in their work areas. On or about December 10, 2018 and at times prior thereto, the employer did not include the methods used to inform employees of the hazards associated with chemicals such as, but not limited to anhydrous ammonia that was located in unlabeled piping or tubing throughout the work areas. This exposed employees to fire/ explosion and chemical hazards.
Recent events (2)
- — I (S) $2000
- — Z (S) $6630
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces were kept in a clean, orderly, and sanitary condition. On or about December 10, 2018 and at times prior thereto, the employer did not ensure the sand blast grit and media were removed form the west shop floors, exposing employees to trip, slip fall hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. On or about December 10, 2018 and at times prior thereto, the employer did not ensure that compressed air used for cleaning was reduced to 30 p.s.i. This exposed employees to struck by hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(a)(1): The employer did not effectively ensure information concerning the hazards of all chemicals to which employees may be exposed to, was transmitted as accomplished by the means of the employer's comprehensive hazard communication programs including labeling and other forms of warning, material safety data sheets and employee training. On or about December 10, 2018 and at times prior thereto, the employer did not ensure safety data sheets were readily available to employees. This exposed employees to hazards associated with chemicals including, but not limited to anhydrous ammonia.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332811)
WATERBURY, CT—2026-05-06
THE NELSON HEAT TREATING COMPANY, INC.
CLINTON TOWNSHIP, MI—2026-05-05
SYNERGY ADDITIVE MANUFACTURING, LLC
LEBANON, OH—2026-04-28
FB ACQUISITION, LLC
LEBANON, OH—2026-04-28
FB ACQUISITION, LLC
EAST GRANBY, CT—2026-04-27
SPECIALTY STEEL TREATING, INCORPORATED
More inspections in OK
TULSA, OK—2026-07-15
LA UNION 7 LLC
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343649133.