Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARGILL HEAT TREAT, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARGILL HEAT TREAT, LLC in 1626 S.E. 40TH, OKLAHOMA CITY, OK 73129 (NAICS 332811). OSHA activity number 343649133.

Watch Cargill Heat Treat, LLC — free Get an email when a new federal OSHA severe-injury report for Cargill Heat Treat, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1626 S.E. 40TH
City
OKLAHOMA CITY
State
OK
ZIP
73129
Mailing
1626 S.E. 40TH, OKLAHOMA CITY, OK 73129
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332811
Employees
26
Ownership type
A

9 citations on file for this inspection.

1910.111 C07

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $6630.00 · Current $2000.00 Reduced
29 CFR 1910.111(c)(7): The employer did not protect ammonia systems from vehicle damage.    On or about December 10, 2018 and at times prior thereto, employees were exposed to storage tanks of anhydrous ammonia  that were not protected from vehicular traffic. Employees were exposed to fire /explosion and chemical hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $6630

1910.124 G02

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $6630.00 · Current $2000.00 Reduced
29 CFR 1910.124(g)(2): Employees who worked with liquids that could burn, irritate, or otherwise harm their skin were not provided with an emergency shower and eye-wash station close to the dipping and coating operation. :Note:  In place of this equipment, the employee may use a water hose that is at least 4 feet (1.22 m) long and at least 3/4 of an inch (18 mm) thick with a quick-opening valve and carrying a pressure of 25 pounds per square inch (1.62 k/cm2) or less.    On or about December 10, 2018 and at times prior thereto, employees were not provided an emergency shower and eyewash station while working with corrosive chemicals such as, but not limited to anhydrous ammonia, sand blast media, degreaser wash solution.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $6630

1910.147 A03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6630.00 · Current $2000.00 Reduced
29 CFR 1910.147(a)(3)(i): Employer failed to establish a program and utilize procedures for affixing appropriate lockout devices or tagout devices to energy isolating devices, and to otherwise disable machines or equipment to prevent unexpected energization, start up or release of stored energy in order to prevent injury to employees.    On or about December 10, 2018 and at times prior thereto, the employer did not establish and utilize an energy control program and procedures to ensure machines are disabled and cannot unexpectedly startup. Employees were exposed to hazards including fire/explosion and chemical exposure.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $6630

1910.178 L01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $5304.00 · Current $2000.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    On or about December 10, 2018 and at times prior thereto, the employer did not ensure that employees operating powered industrial trucks received training. This exposed employees to struck by and crushed by hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $5304

1910.303 B07 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $5304.00 · Current $2000.00 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment    On or about December 10, 2018 and at times prior thereto, the employer did not ensure that the blanks and covers were installed on electrical panels in the SW and NE corners of the West shop bldg. This exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $5304

1910.1200 E01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $6630.00 · Current $2000.00 Reduced
29 CFR 1910.1200(e)(1)(ii): The written hazard communication program did not include the methods the employer would use to inform employees of the hazards of non-routine tasks, and the hazards associated with chemicals contained in unlabeled pipes in their work areas.      On or about December 10, 2018 and at times prior thereto, the employer did not include the methods used to inform employees of the hazards associated with chemicals such as, but not limited to anhydrous ammonia that was located in unlabeled piping or tubing throughout the work areas.  This exposed employees to fire/ explosion and chemical hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $6630

1910.22 A01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces were kept in a clean, orderly, and sanitary condition.  On or about December 10, 2018 and at times prior thereto, the employer did not ensure the sand blast grit and media were removed form the west shop floors, exposing employees to trip, slip fall hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.242 B

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  On or about December 10, 2018 and at times prior thereto, the employer did not ensure that compressed air used for cleaning was reduced to 30 p.s.i. This exposed employees to struck by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 A01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(a)(1): The employer did not effectively ensure information concerning the hazards of all chemicals  to which employees may be exposed to, was transmitted as accomplished by the means of the employer's comprehensive hazard communication programs including labeling and other forms of warning, material safety data sheets and employee training.  On or about December 10, 2018 and at times prior thereto, the employer did not ensure safety data sheets were readily available to employees. This exposed employees to hazards associated with chemicals including, but not limited to anhydrous ammonia.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343649133.