1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: BDG WRAP-TITE, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BDG WRAP-TITE, INC in 6200 COCHRAN ROAD, SOLON, OH 44139 (NAICS 326112). OSHA activity number 343657680.

Watch BDG Wrap-Tite, INC — free Get an email when a new federal OSHA severe-injury report for BDG Wrap-Tite, INC is published. One employer, no account, unsubscribe in one click.
Establishment
BDG WRAP-TITE, INC
Site address
6200 COCHRAN ROAD
City
SOLON
State
OH
ZIP
44139
Mailing
6200 COCHRAN ROAD, SOLON, OH 44139
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326112
Employees
80
Ownership type
A

2 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9282.00 · Current $5400.00 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:       On or about December 14, 2018, an employee was exposed to a machine hazard associated with moving parts and an in-going nip point hazard during a maintenance servicing task while cleaning the fluff grinder cyclone at the #3 extruder machine in the unit B area. The employer failed to implement energy control application steps as LOTO devices were not applied to the electrical disconnect [per the 1910.147(d)(4) requirements]. As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.     prepare for shutdown [(d)(1)]; - ensure authorized employee has knowledge of the type, magnitude, the hazard, and the method or means to control the energy;    shutdown the machine or equipment [(d)(2)];    machine isolation [(d)(3)]; physically locate and operate all energy isolating devices that are needed to control the energy to the machine or equipment in such a manner as to isolate the machine or equipment from the energy source(s);    LOTO device application [(d)(4)]; affix a lockout or tagout device to each energy isolating device;    dissipation of residual energy [(d)(5)(i)];    relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy;  verification of isolation [(d)(6)];    verify that isolation and deenergization of the machine or equipment has been accomplished;
Recent events (2)
  • — I (S) $5400
  • — Z (S) $9282

1910.212 A02

Other-than-serious 2 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:  On or about December 14, 2018, the motor to the gear box assemblies at the E3 extrusion machine had coupling guards that were not completely affixed and secured in place over the rotating couplings.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BDG WRAP-TITE, INC's full OSHA safety record →