MELBOURNE, FL —
OSHA Inspection: WINCHESTER INTERCONNECT CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WINCHESTER INTERCONNECT CORPORATION in 3950 DOW ROAD, MELBOURNE, FL 32934 (NAICS 334511). OSHA activity number 343660569.
Where did this inspection happen?
- Establishment
- WINCHESTER INTERCONNECT CORPORATION
- Site address
- 3950 DOW ROAD
- City
- MELBOURNE
- State
- FL
- ZIP
- 32934
- Mailing
- 3950 DOW ROAD, MELBOURNE, FL 32934
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334511
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $4989.00 · Current $2993.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Chemical Room - A written program was not developed and air purifying respirators were required to be worn, on or about December 13, 2018.
Recent events (2)
- — I (S) $2993.4
- — Z (S) $4989
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Chemical Room - Air purifying respirators were required to be worn and no medical evaluations were conducted, on or about December 13, 2018.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Chemical Room - Air purifying respirators were required to be worn and no fit tests were conducted, on or about December 13, 2018.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 334511)
MELBOURNE, FL—2026-07-07
LEONARDO DRS, INC.
SAINT LOUIS, MO—2026-06-12
MCCAY TOOL & ENGINEERING CO. INC.
ARLINGTON, WA—2026-05-19
WA317991298 - INOV8V MARINE GROUP INC
FAIRFIELD, CA—2026-05-15
ROCKWELL COLLINS INC.
VICTORVILLE, CA—2026-05-04
COMAV
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343660569.