Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WINCHESTER INTERCONNECT CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WINCHESTER INTERCONNECT CORPORATION in 3950 DOW ROAD, MELBOURNE, FL 32934 (NAICS 334511). OSHA activity number 343660569.

Watch Winchester Interconnect Corporation — free Get an email when a new federal OSHA severe-injury report for Winchester Interconnect Corporation is published. One employer, no account, unsubscribe in one click.
Site address
3950 DOW ROAD
City
MELBOURNE
State
FL
ZIP
32934
Mailing
3950 DOW ROAD, MELBOURNE, FL 32934
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334511
Employees
5
Ownership type
A

3 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4989.00 · Current $2993.00 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    a) Chemical Room - A written program was not developed and air purifying respirators were required to be worn, on or about December 13, 2018.
Recent events (2)
  • — I (S) $2993.4
  • — Z (S) $4989

1910.134 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) Chemical Room - Air purifying respirators were required to be worn and no medical evaluations were conducted, on or about December 13, 2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  a) Chemical Room - Air purifying respirators were required to be worn and no fit tests were conducted, on or about December 13, 2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

COMAV