Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SPECIALIZED MANUFACTURING, LTD.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SPECIALIZED MANUFACTURING, LTD. in 8101 FITE RD., PEARLAND, TX 77581 (NAICS 332999). OSHA activity number 343661930.

Watch Specialized Manufacturing, LTD. — free Get an email when a new federal OSHA severe-injury report for Specialized Manufacturing, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
8101 FITE RD.
City
PEARLAND
State
TX
ZIP
77581
Mailing
8101 FITE RD., PEARLAND, TX 77584
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
20
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $4546.00 · Current $2728.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts:  a) At the facility, where the rotating parts in the Leadwell LTC-30BPL CNC machine, serial number L2SIG0339 were not guarded.  The door interlock was not operational.  b) At the facility, in the fabrication area, where the point of operation was not guarded on the 250 ton Pacific Press machine.  c) At the facility, in the clap area, where the point of operation was not guarded on the 12 ton #2 punch press machine.  d) At the facility, in the clap area, where the point of operation was not guarded on the small press brake machine.
Recent events (2)
  • — I (S) $2727.6
  • — Z (S) $4546

1910.303 G02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3789.00 · Current $2273.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) In the fabrication area against the wall, where the electrical panel was missing the dead front cover.
Recent events (2)
  • — I (S) $2273.4
  • — Z (S) $3789

1910.1200 G08

Other-than-serious 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $425.00 · Current $255.00 Reduced
29 CFR 1910.1200(g)(8):  The employer did not maintain in the workplace copies of the required safety data sheets (SDSs)for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):  a) At the facility, where the employer did not ensure that the safety data sheet for Trim Sol was maintained at the facility.  Trim Sol contains severely hydrotreated petroleum oil.  b) At the facility, where the employer did not ensure that the safety data sheet for Carbon Steel welding wire was maintained at the facility.  The welding wire contains substances such as, but not limited to, iron, manganese, copper, nickel, carbon, and chromium.
Recent events (2)
  • — I (O) $255
  • — Z (O) $425