1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: FLASHCO MANUFACTURING, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FLASHCO MANUFACTURING, INC. in 2200 S BUSSE SUITE B, MOUNT PROSPECT, IL 60056 (NAICS 332999). OSHA activity number 343680732.

Watch Flashco Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Flashco Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2200 S BUSSE SUITE B
City
MOUNT PROSPECT
State
IL
ZIP
60056
Mailing
150 TODD RD., SANTA ROSA, CA 95407
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
9
Ownership type
A

5 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $5304.00 · Current $4400.00 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    Employees were exposed to injury from a projectile hazard. Compressed gas cylinder that were not in use, were not secured to prevent damage in accordance as required by Compressed Gas Association Pamphlet P-1-1965 in the following location:    a) On December 21, 2018, three compressed gas cylinders located next to the automatic welder were not secured.      No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $4400
  • — Z (S) $5304

1910.252 B02 III

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $5304.00 · Current $0.00 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:    a) Automatic Welder- On or about December 21, 2018, Flashco Manufacturing, Inc. did not ensure that workers adjacent to the automatic welding area were adequately protected from rays by noncombustible or flameproof screens or shields.      No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5304

1910.1025 D06 II

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $6630.00 · Current $4000.00 Reduced
29 CFR 1910.1025(d)(6)(ii): Where the initial determination or subsequent monitoring revealed employee exposure to lead to be at or above the action level but below the permissible exposure limit; monitoring was not repeated at least every six months:    a) On December 21, 2018, the employer did not repeat monitoring within six months of monitoring revealed employee exposure to lead to be above the action level. The employer's monitoring revealed employee exposure to lead at 32 ug/m3  and  42 ug/m3 respectively on April 2, 2018.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $4000
  • — Z (S) $6630

1910.1025 H01

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $9282.00 · Current $4400.00 Reduced
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:    a) The employer did not maintain all surfaces as free as practicable of accumulation of lead. On December 21, 2018, wipe samples taken at this site indicated the presence of lead on the north lunchroom table and the east water fountain to be 1282 micrograms and 1587 micrograms respectively.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $4400
  • — Z (S) $9282

1910.1025 E04 II

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1025(e)(4)(ii): Air from an exhaust ventilation system used to control exposure to lead was recirculated and no controls were monitoring the concentration of lead in the return air:    a) On January 15, 2019, the employer used an ACSI model FA2000EC air filtration unit to control exposure to lead and recirculated the air from this system in the return air of the facility. There were no controls in place to monitor the concentration of lead in the return air.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343680732.