Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: POTLATCHDELTIC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of POTLATCHDELTIC in 729 EAST HWY 10, OLA, AR 72853 (NAICS 321113). OSHA activity number 343702635.

Watch Potlatchdeltic — free Get an email when a new federal OSHA severe-injury report for Potlatchdeltic is published. One employer, no account, unsubscribe in one click.
Establishment
POTLATCHDELTIC
Site address
729 EAST HWY 10
City
OLA
State
AR
ZIP
72853
Mailing
P.O. BOX 129, OLA, AR 72853
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
145
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $11934.00 · Current $11934.00
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  a) Debarker #1: On or about January 9, 2019 and a times prior, clear and specific energy control procedures were not developed and utilized to isolate and bleed off all energy sources including but not limited to the hydraulic system. Employees were exposed to the unexpected start up or release of residual energy while clearing jams.
Recent events (1)
  • — Z (S) $11934

1910.147 C07 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i)(A): Authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  a) Debarker #1: On or about January 9, 2019 and a times prior, authorized employees were not trained on specific energy control procedures to isolate and bleed off all energy sources including but not limited to the hydraulic system. Employees were exposed to the unexpected start up or release of residual energy while clearing jams.
Recent events (1)
  • — Z (S) $0

1910.147 C05 II B

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $957.00 · Current $957.00
29 CFR 1910.147(c)(5)(ii)(B): Lockout and tagout devices were not standardized within the facility in at least one of the following criteria: color; shape; or size:   a) OLI Machine: On or about January 09, 2019, employees were performing lockout with devices that were not standardized and identified as lockout devices.
Recent events (1)
  • — Z (O) $957

View POTLATCHDELTIC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343702635.