WATKINS GLEN, NY —
OSHA Inspection: WILLIAMS CONSTRUCTION & SPRAYFOAM, LLC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WILLIAMS CONSTRUCTION & SPRAYFOAM, LLC. in 29 NORTH FRANKLIN STREET, WATKINS GLEN, NY 14891 (NAICS 238130). OSHA activity number 343728010.
Where did this inspection happen?
- Establishment
- WILLIAMS CONSTRUCTION & SPRAYFOAM, LLC.
- Site address
- 29 NORTH FRANKLIN STREET
- City
- WATKINS GLEN
- State
- NY
- ZIP
- 14891
- Mailing
- 1251 PENNSYLVANIA AVENUE, PINE CITY, NY 14871
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 22
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.304 F
- Issued
- Abate by
- Penalty
- Initial $4168.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) First floor, on or about 1-15-19: Three employees were ripping framing lumber on a table saw that was not equipped with non kick-back fingers or "dogs". b) First floor, on or about 1-15-19: Three employees were framing lumber on a table saw that was not equipped with a magnetic switch or anti-restart device. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM
Recent events (3)
- — J (S) $0
- — C (S) $4168
- — Z (S) $4168
1926.304 I
- Issued
- Abate by
- Penalty
- Initial $4168.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) First floor, on or about 1-15-19: Three employees were ripping framing lumber on a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade.
Recent events (3)
- — J (S) $0
- — C (S) $4168
- — Z (S) $4168
1926.451 G04 I
- Issued
- Abate by
- Penalty
- Initial $4168.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: a) South side of building, on or about 1-15-19: One employee was working on a prefabricated aluminum plank while connected to a safety rope that was rigged with excess slack, such that the employee could fall more than 6 feet, exposing the employees to a fall hazard of 12 feet 3 inches.
Recent events (3)
- — J (S) $0
- — C (S) $4168
- — Z (S) $4168
1926.502 D16 III
- Issued
- Penalty
- Initial $4168.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) South side of building, on or about 1-15-19: One employee was working on a prefabricated aluminum plank while connected to a safety rope that was rigged with excess slack, such that the employee could fall more than 6 feet, exposing the employees to a fall hazard of 12 feet 3 inches.
Recent events (3)
- — J (S) $0
- — C (S) $4168
- — Z (S) $4168
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $4168.00 · Current $4168.00
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) South side of building, southeast corner, on or about 1-15-19: Three employees were working at the edge of an open sided floor deck, without fall protection, exposing the employees to a fall hazard of 12 feet 3 inches to the ground below. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM
Recent events (3)
- — J (S) $4168
- — C (S) $4168
- — Z (S) $4168
1926.501 B04
- Issued
- Abate by
- Penalty
- Initial $4168.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(4): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a) Southeast corner of building, second floor, on or about 1-15-19: Three employees were working in the vicinity of a stair opening, without fall protection, exposing the employees to a fall hazard of 12 feet 10 inches to the concrete floor below. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM
Recent events (3)
- — J (S) $0
- — C (S) $4168
- — Z (S) $4168
1926.1053 B01
- Issued
- Penalty
- Initial $3334.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) West side of building, back, on or about 1-15-19: Three employees were accessing the second floor deck of a building via a portable extension ladder that was not extended 3 feet above the landing surface, exposing the employees to fall hazards of 12 feet 3 inches to the ground below.
Recent events (3)
- — J (S) $0
- — C (S) $3334
- — Z (S) $3334
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343728010.