1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ENERFAB PROCESS SOLUTIONS & FABRICATED PRODUCTS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ENERFAB PROCESS SOLUTIONS & FABRICATED PRODUCTS, INC. in 1000 FERRY ROAD, WILMINGTON, DE 19801 (NAICS 238990). OSHA activity number 343730859.

Watch Enerfab Process Solutions & Fabricated Products, INC. — free Get an email when a new federal OSHA severe-injury report for Enerfab Process Solutions & Fabricated Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1000 FERRY ROAD
City
WILMINGTON
State
DE
ZIP
19801
Mailing
4955 SPRING GROVE AVENUE, CINCINNATI, OH 45232
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
275
Ownership type
A

5 citations on file for this inspection.

1926.1204 E01 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $0.00 Reduced
29 CFR 1926.1204(e)(1)(i): (i) The employer did not perform pre-entry testing to the extent feasible before entry is authorized;   a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019 the employer failed to perform pre-entry testing before entering the tank which is classified as a permit required confined space.
Recent events (3)
  • — J (S) $0
  • — C (S) $13260
  • — Z (S) $13260

1926.1204 E01 II

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1204(e)(1)(ii): (ii) If entry is authorized, continuously monitor entry conditions in the areas where authorized entrants are working, except that employers may use periodic monitoring in accordance with paragraph (e)(2) of this section for monitoring an atmospheric hazard if they can demonstrate that equipment for continuously monitoring that hazard is not commercially available;  a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019, the employer failed to ensure that the juice tank, which is classified as a permit required confined space was not continuously monitored to ensure that no atmospheric hazard was present when entered by an employee.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1204 F

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $0.00 Reduced
29 CFR 1926.1204(f): 29 CFR 1926.1204(f): An attendant was not provided outside a permit confined space for the duration of entry operations:  a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019, the employer failed to provide an attendant when an employee entered the tank which is classified as a permit required confined space.
Recent events (3)
  • — J (S) $0
  • — C (S) $13260
  • — Z (S) $13260

1926.1204 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $0.00 Reduced
29 CFR 1926.1204(i): 29 CFR 1926.1204(i): The employer did not develop and implement procedures for summoning rescue and emergency services (including procedures for summoning emergency assistance in the event of a failed non-entry rescue), for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue:  a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9. 2019, the employer failed to implement procedures for summoning rescue services when a competent person entered a juice tank that was classified as a permit required confined space.
Recent events (3)
  • — J (S) $0
  • — C (S) $13260
  • — Z (S) $13260

1926.1205 A

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $0.00 Reduced
29 CFR 1926.1205(a): 29 CFR 1926.1205(a): Before entry was authorized, the employer did not document the completion of measures required by paragraph 1926.1204(c) of this standard by preparing an entry permit:   a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019, the employer failed to prepare an entry permit prior to the competent person entering the juice tank, which is classified as a permit required confined space.
Recent events (3)
  • — J (S) $0
  • — C (S) $13260
  • — Z (S) $13260

View ENERFAB PROCESS SOLUTIONS & FABRICATED PRODUCTS, INC.'s full OSHA safety record →