HAMBURG, PA —
OSHA Inspection: DOVE PLASTICS, INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DOVE PLASTICS, INCORPORATED in 111 VALLEY ROAD, HAMBURG, PA 19526 (NAICS 333249). OSHA activity number 343736831.
Where did this inspection happen?
- Establishment
- DOVE PLASTICS, INCORPORATED
- Site address
- 111 VALLEY ROAD
- City
- HAMBURG
- State
- PA
- ZIP
- 19526
- Mailing
- 111 VALLEY ROAD, HAMBURG, PA 19526
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333249
- Employees
- 23
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.303 B01 VIII
- Issued
- Abate by
- Penalty
- Initial $5304.00 · Current $5304.00
General-duty citation text
29 CFR 1910.303(b)(1)(viii): Safety of equipment was not determined using considerations for other factors which contributed to the practical safeguarding of employees using or likely to come in contact with the equipment: a) 111 Valley Rd., Hamburg, PA - The #3 blow molding unit was not free from recognized electrical hazards. On or about January 24, 2019, employees performing production and maintenance activities are exposed to electrical shock and fire hazards from contact with machine parts that were not properly safeguarded for the following reasons: 1- open wire-nut terminations within machine. b) 111 Valley Rd., Hamburg, PA - The #8 blow molding unit was not free from recognized electrical hazards. On or about January 24, 2019, employees performing production and maintenance activities are exposed to electrical shock and fire hazards from contact with machine parts that were not properly safeguarded for the following reasons: 1- broken conduit connections on west side of machine 2- flexible wiring not provided with outer protective jacket on west side of machine. 3- cracked timer cover exposing inside of control panel. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- — Z (S) $5304
1910.303 C03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose: a) 111 Valley Rd., Hamburg, PA - On or about January 24, 2019, the #8 machine contained splices that were not covered with an insulation equivalent to that of the conductors or with an insulating device: 1- open splice electrical connections on east side of machine. b) 111 Valley Rd., Hamburg, PA - 111 Valley Rd., Hamburg, PA - On or about January 24, 2019, the #9 machine contained splices that were not covered with an insulation equivalent to that of the conductors or with an insulating device: 1- non-bushed flexible wiring exiting control panel with open splices. 2- open splice connection on top of machine. 3- open splice connection on lower side of machine east side. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $1932.00 · Current $1932.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) 111 Valley Rd., Hamburg, PA - The employer is utilizing both double and single metallic gang boxes as pendent drops for shop equipment use in the maintenance department on or about January 24, 2019. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $1932
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) 111 Valley Rd., Hamburg, PA - On or about January 24, 2019, the #3 blow molding machine was not provided with covers for the following areas to afford protection equivalent to the wall of the equipment. 1- electrical junction box not provided with cover plate at rear of machine 2- missing timer cover on service panel cabinet. b) 111 Valley Rd., Hamburg, PA - An energized metallic gang box located in the maintenance department and used as a pendant drop is not effectively closed in that an unused knockout opening exists on or about January 24, 2019. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) 111 Valley Rd., Hamburg, PA - at Dove Plastics Incorporated, an evaluation of each powered industrial truck operator's performance had not been conducted at least once every three years, such as, but not limited to, employees operating the Yale forklift truck without current training on or about January 24, 2019. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables are not to be used as a substitute for the fixed wiring of a structure: a) 111 Valley Rd., Hamburg, PA - On or about January 24, 2019, in the maintenance department, the yellow extension cord, energized from a permanent receptacle and routed along the block wall and zip-tied to SO cord to energize a work light, was being used in lieu of permanent wiring. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 333249)
NORTON SHORES, MI—2026-06-30
I D SYSTEMS INC DBA INTER DYNE SYSTEMS
SAINT LOUIS, MO—2026-06-23
WEIR MINERALS LEWIS PUMPS
AUBURN HILLS, MI—2026-06-10
ANDROID INDUSTRIES LLC
EGG HARBOR TOWNSHIP, NJ—2026-06-09
JOMAR CORPORATION
BUTTE, MT—2026-05-27
RESODYN CORPORATION
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343736831.