SYRACUSE, NY —
OSHA Inspection: TRADE-MARK CONSTRUCTION OF SYRACUSE INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of TRADE-MARK CONSTRUCTION OF SYRACUSE INC. in 709 NORTH SALINA STREET, SYRACUSE, NY 13208 (NAICS 238990). OSHA activity number 343737086.
Where did this inspection happen?
- Establishment
- TRADE-MARK CONSTRUCTION OF SYRACUSE INC.
- Site address
- 709 NORTH SALINA STREET
- City
- SYRACUSE
- State
- NY
- ZIP
- 13208
- Mailing
- 210 WOLF STREET, SYRACUSE, NY 13208
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 17
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.403 I02 I
- Issued
- Penalty
- Initial $5304.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) At the jobsite, in the basement, on or about 1/24/19: Workers were exposed to live electrical conductors where a service panel was unguarded/uncovered.
Recent events (3)
- — J (S) $1000
- — C (S) $5304
- — Z (S) $5304
1926.403 B01 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. a) At the jobsite, on or about 1/24/19: Workers used tools that were plugged into quad outlet boxes wired and used as extension cords, and not designed for that purpose.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.404 B01 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) At the jobsite, on or about 1/24/19: Workers were using power tools and appliances that were energized by connections to building power that was not GFI protected.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Penalty
- Initial $5304.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) At the jobsite, on or about 1/24/19: A worker was standing on the sill of a window opening without fall protection, and exposed to a 12 foot fall to the sidewalk. b) At the jobsite, on or about 1/24/19: Employees were working in close proximity to 5 unguarded window openings where the sills were 2 feet from the second floor deck and where workers were exposed to a 10 foot fall without fall protection.
Recent events (3)
- — J (S) $1000
- — C (S) $5304
- — Z (S) $5304
1926.502 I03
- Issued
- Penalty
- Initial $3031.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: a) At the jobsite, on or about 1/24/19: Hole covers were not secured to the deck to prevent displacement.
Recent events (3)
- — J (S) $500
- — C (S) $3031
- — Z (S) $3031
1926.502 I04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: a) At the jobsite, on or about 1/24/19: Hole covers were not marked appropriately to indicate HOLE or COVER.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at TRADE-MARK CONSTRUCTION OF SYRACUSE INC.
SOLVAY, NY—2021-07-22 00:00:00
TRADE-MARK CONSTRUCTION OF SYRACUSE, INC.
NEW HARTFORD, NY—2020-01-29 00:00:00
TRADE-MARK CONSTRUCTION OF SYRACUSE, INC.
View TRADE-MARK CONSTRUCTION OF SYRACUSE INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
EL PASO, TX—2026-07-09
RM CRANE & RIGGING LLC.
LAKEWOOD, WA—2026-07-08
WA317992018 - HARMON INC DBA HARMON SERVICE GLAZING INC
VICTOR, NY—2026-07-08
DIMARCO CONSTRUCTORS
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343737086.