Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SRB HOMES, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SRB HOMES, LLC in 228 HIGHLAND AVE, GARDINER, ME 04345 (NAICS 236118). OSHA activity number 343737995.

Watch SRB Homes, LLC — free Get an email when a new federal OSHA severe-injury report for SRB Homes, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SRB HOMES, LLC
Site address
228 HIGHLAND AVE
City
GARDINER
State
ME
ZIP
04345
Mailing
701 SOUTH UNION RD, UNION, ME 04862
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.62 D02 V F

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $1421.00 Reduced

Hazardous substances 1591

29 CFR 1926.62(d)(2)(v)(F):     The employer did not provide training as required under paragraphs (l)(1)(i) of this section regarding 29 CFR 1926.59, Hazard Communication; and training as required under paragraph (l)(2)(iii) of this section regarding use of respirators; and training in accordance with 29 CFR 1926.21 Safety training and education:
Recent events (2)
  • — I (S) $1421
  • — Z (S) $2842

1926.405 B01

Serious Gravity 5 12 instances 3 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $1421.00 Reduced
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:    In the following instances, unused openings were not effectively closed:    a)  Basement panel contained 6 open breaker slots.  b)  Receptacle and switch covers were missing on the first floor.
Recent events (2)
  • — I (S) $1421
  • — Z (S) $2842

1926.1052 C01 II

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $1421.00 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:    In the following instances, stairways were not equipped with stairrail systems:    a)  Ten riser basement stairway.  b)  Four riser kitchen stairway to landing.  c)  Eight riser kitchen stairway from landing to second floor.
Recent events (2)
  • — I (S) $1421
  • — Z (S) $2842

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343737995.