1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: HINKLEY LIGHTING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HINKLEY LIGHTING, INC. in 33000 PIN OAK PARKWAY, AVON LAKE, OH 44012 (NAICS 423990). OSHA activity number 343745915.

Watch Hinkley Lighting, INC. — free Get an email when a new federal OSHA severe-injury report for Hinkley Lighting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
33000 PIN OAK PARKWAY
City
AVON LAKE
State
OH
ZIP
44012
Mailing
33000 PIN OAK PARKWAY, AVON LAKE, OH 44012
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423990
Employees
126
Ownership type
A

4 citations on file for this inspection.

1910.178 L03 I M

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $6521.00 · Current $3260.00 Reduced
29 CFR 1910.178(l)(3)(i)(M): Powered industrial truck operators did not receive initial training on truck-related topics including operating instructions, warnings, or precautions listed in the operators manual for the types of vehicles that the employees were trained to operate.    On or about January 28, 2019, employees that used the Clark forklift (model GCX17E; s/n GX177E-0148-9345K0F) to load/unload semi-trailers were exposed to drop-off hazards in that they were not trained in operating instructions of securing the trailers with a dock lock system or wheel blocks.
Recent events (2)
  • — I (S) $3260
  • — Z (S) $6521

1910.178 M07

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(m)(7): Brakes were not set and wheel blocks were not in place to prevent movement of trucks, trailers, or railroad cars while loading and unloading:   On or about January 28, 2019, the employer did not ensure that truck trailers were secured to protect employees from drop-off hazards when using a forklift to access the trailers in that wheel blocks were not used to prevent trailer movement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $6521.00 · Current $3261.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a. On or about January 24, 2019, the employer did not ensure that the Yang Iron Works lathe (mfg. no. 059684) located in the tool room was guarded to protect employees from rotating part hazards.     b. On or about January 27, 2019, the National shear, located in the tool room, was not guarded to protect employees from amputation injury.  The employer did not ensure the employees were adequately protected from pinch point hazards created by the blade and hold-down mechanism.
Recent events (2)
  • — I (S) $3261
  • — Z (S) $6521

1910.178 Q07

Other-than-serious 1 instance 50 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  On or about January 28, 2019, powered industrial trucks were not inspected daily and/or before each shift, for conditions that adversely affect the truck's safety.  Employees operate the industrial trucks daily to load/unload trucks and move materials in the storage areas.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View HINKLEY LIGHTING, INC.'s full OSHA safety record →