Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DMP CONSTRUCTION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DMP CONSTRUCTION, LLC in 53 PINECREST AVE., ORANGE, CT 06477 (NAICS 238130). OSHA activity number 343778783.

Watch DMP Construction, LLC — free Get an email when a new federal OSHA severe-injury report for DMP Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
53 PINECREST AVE.
City
ORANGE
State
CT
ZIP
06477
Mailing
64 MILWAUKEE AVE., BETHEL, CT 06801
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

3 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $319.00 · Current $319.00
29 CFR 1903.19(c)(1): Employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   Location:  53 Pinecrest Avenue, Orange, CT  06477  Abatement certification and verification for Citation 001, Item 01b with a final order date of March 20, 2019  was not received within 10 calendar days (by April 11, 2019) following the abatement due date (April 1, 2019).
Recent events (1)
  • — Z (O) $319

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $2785.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b).    Worksite: The employer did not ensure that the employee working on the roof of the residential garage under renovation was protected from fall hazards above 6 feet by the use of guardrails, safety nets or a personal fall arrest system.    On or about 02/08/2019, the employee fell from the roof while installing a beam in the garage and sustained minor injuries from the incident.
Recent events (2)
  • — I (S) $2784.6
  • — Z (S) $3978

1926.503 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards.    Worksite: The employer did not ensure that the employee exposed to fall hazards at a height above 6 feet was provided with training and information in fall hazards and the procedures to be followed to minimize such hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343778783.