IMPERIAL, PA —
OSHA Inspection: DUERR PACKAGING COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DUERR PACKAGING COMPANY, INC. in 8152 STEUBENVILLE PIKE, IMPERIAL, PA 15126 (NAICS 326150). OSHA activity number 343797908.
Where did this inspection happen?
- Establishment
- DUERR PACKAGING COMPANY, INC.
- Site address
- 8152 STEUBENVILLE PIKE
- City
- IMPERIAL
- State
- PA
- ZIP
- 15126
- Mailing
- 8152 STEUBENVILLE PIKE, IMPERIAL, PA 15126
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326150
- Employees
- 25
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A03 II
- Issued
- Penalty
- Initial $5304.00 · Current $3200.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Facility: On or before February 21, 2019, the employer did not ensure the guard extended to prevent incidental contact with the blade during corner shearing at the point of operation. The machine was manufactured by the MD Knowlton Company.
Recent events (2)
- — I (S) $3200
- — Z (S) $5304
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section: a) Facility: On or before February 21, 2019, the employer did not include a specific purpose and scope of when to use hazardous energy control procedures such as mold changeovers on the Fucecchio machine(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Facility: On or before February 21, 2019, the employer did not conduct a periodic inspection on the implementation of their energy control procedures on equipment such as the B-1 Stokes and Smith.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: a) Facility: On or before February 21, 2019, the employer did not train production employees to an authorized level to conduct mold changeovers on the Emmeci Fucecchio machine(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326150)
CORRY, PA—2026-06-25
FXI, INC.
TRION, GA—2026-06-15
FOAM PRODUCTS CORP.
RIDGEWAY, VA—2026-06-15
ATLAS ROOFING CORPORATION
RIDGEWAY, VA—2026-06-15
ATLAS ROOFING CORPORATION
LEXINGTON, KY—2026-06-04
69182 - FOAM DESIGN INC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343797908.