Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PORTLAND STEEL INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PORTLAND STEEL INC in 394 DELAWARE AVE, PORTLAND, PA 18351 (NAICS 332312). OSHA activity number 343807830.

Watch Portland Steel INC — free Get an email when a new federal OSHA severe-injury report for Portland Steel INC is published. One employer, no account, unsubscribe in one click.
Establishment
PORTLAND STEEL INC
Site address
394 DELAWARE AVE
City
PORTLAND
State
PA
ZIP
18351
Mailing
394 DELAWARE AVE, PORTLAND, PA 18351
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
3
Ownership type
A

6 citations on file for this inspection.

1910.101 B

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $1705.00 · Current $550.00 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:     a) Shop area - on or about February 25, employees were working in the area where an unsecured oxygen cylinder was stored.    Abatement Note: The in-plant handling, storage, and utilization of all compressed gases related to cylinder storage is addressed in CGA P-1-1965, Section 3.4.4, which states, "Before using cylinder, be sure it is properly supported to prevent it from being knocked over".
Recent events (2)
  • — I (O) $550
  • — Z (S) $1705

1910.157 C01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $900.00 Reduced
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.    a) 394 Delaware Ave, Portland, PA 18351  - on or about February 25, 2019, employees were working in a fabrication shop with flammable gasses and liquids in the work area, but a portable fire extinguisher was not readily accessible for employee use in the event of an incipient stage fire.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1705

1910.242 B

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1100.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i:    a) Facility wide - On or about February 25, 2019, employees were using compressed air nozzles for cleaning work that did not have the air pressure reduced to less than 30 pounds per square inch.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2273

1910.303 B02

Serious Gravity 5 10 instances 3 exposed
Issued
Abate by
Penalty
Initial $3410.00 · Current $2000.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Facility wide - On or about February 25, 2019, multiple knockout style outlet boxes, energized to 120 vAC, were in use for pendant wiring and not mounted in accordance with their listing and labeling.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3410

1910.305 G01 IV A

Serious Gravity 5 10 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  Facility wide - On or about February 25, 2019, flexible cords were being used to power receptacles and equipment as a substitute for the fixed wiring of the workplace.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 10 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.  a)  Facility wide - On or about February 25, 2019, flexible cords were being used to power receptacles and equipment and were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View PORTLAND STEEL INC's full OSHA safety record →