NEW ALBANY, OH —
OSHA Inspection: NERY BONILLO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NERY BONILLO in 4248 HARLEM ROAD, NEW ALBANY, OH 43054 (NAICS 238160). OSHA activity number 343819017.
Where did this inspection happen?
- Establishment
- NERY BONILLO
- Site address
- 4248 HARLEM ROAD
- City
- NEW ALBANY
- State
- OH
- ZIP
- 43054
- Mailing
- 1620 DUXBERRY AVENUE, COLUMBUS, OH 43219
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $3978.00
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. a. On or before February 28, 2019, the employer failed to initiate and maintain a safety and health program such as but not limited to a personal protective equipment program, thereby exposing employees to struck-by hazards. b. On or before February 28, 2019, the employer failed to initiate and maintain a safety and health program such as but not limited to a fall protection program, thereby exposing employees to 12 foot 6 inch fall hazards. c. On or before February 28, 2019, the employer failed to initiate and maintain a safety and health program such as but not limited to a ladder safety program, thereby exposing employees to 12 foot 6 inch fall hazards.
Recent events (1)
- — Z (S) $3978
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $2842.00
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a. On or before February 28, 2019, where employees were using pneumatic nail guns to secure roofing materials, the employee's eyes were not protected from flying objects, thereby being exposed to struck-by hazards.
Recent events (1)
- — Z (S) $2842
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $2842.00
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. a. On or before February 28, 2019, where employees were roofing a single family house, the employees were not protected from falls, thereby being exposed to a 12 foot, 6 inch fall hazard.
Recent events (1)
- — Z (S) $2842
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $2842.00
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a. On or before February 28, 2019, where employees used an extension ladder to gain access to the roof of the house, the ladder did not extend at least 3 feet above the edge of the roof, thereby exposing employees to a 12 foot 6 inch fall hazard.
Recent events (1)
- — Z (S) $2842
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in OH
WELLINGTON, OH—2026-07-16