Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DUX PAINT, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of DUX PAINT, LLC in 18 MILL STREET, LODI, NJ 07644 (NAICS 325510). OSHA activity number 343827986.

Watch DUX Paint, LLC — free Get an email when a new federal OSHA severe-injury report for DUX Paint, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DUX PAINT, LLC
Site address
18 MILL STREET
City
LODI
State
NJ
ZIP
07644
Mailing
18 MILL STREET, LODI, NJ 07644
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
11
Ownership type
A

8 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3031.00 · Current $1819.00 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  a) Labeling Shop: A designated emergency exit was locked from the inside, via roll up security gate, thus impeding safe escape from the building, on or about 4/16/19.
Recent events (2)
  • — I (S) $1818.6
  • — Z (S) $3031

1910.37 A03

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a) Labeling Shop: A designated emergency exit was blocked by pallets of empty five gallon containers and other equipment, thus impeding safe escape from the building, on or about 4/16/19.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.106 E06 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3789.00 · Current $2273.00 Reduced
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected:  a) Filling Shop: Employees are required to dispense flammable liquids, including but not limited to, Midwest Topcoat, Part B, a Category 2 flammable liquid, from a large tote into various size containers. The employer did not ensure that employees  dispensed flammable liquids via proper bonding and grounding of containers, on or about 4/16/19.
Recent events (2)
  • — I (S) $2273.4
  • — Z (S) $3789

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   a) Batch Making: An employee is required to wear a 3M full face dual cartridge respirator while engaged in batch making operations. The employer did not provide a medical evaluation to determine the employee's ability to wear a respirator, on or about 3/6/19 and 4/16/19.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.303 G01

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) Labeling Shop: The front area of an electrical panel rated at 250 volts, used to power shop lights, an outlet heater and a ceiling fan, was blocked by pallets of empty five gallon containers, on or about 4/16/19.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a) Paint Labeling Shop: An electrical outlet used to service a nearby stapling machine was missing a cover plate, on or about 4/16/19.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.134 K06

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  a) Batch Making Shop: Employees are allowed to voluntarily wear respirators, including but not limited to, 3M half mask respirators and N95 filtering facepiece dust masks while engaged in batch making of paint and tank cleaning operations. The employer did not provide basic advisory information on the voluntary use of respirators for affected employees, on or about 3/6/19 and 4/16/19.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G06 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(6)(ii): Chemical manufacturers or importers did not ensure that distributors and employers were provided an appropriate safety data sheet with their initial shipment, and/or with the first shipment after a material safety data sheet was updated:  a) Facility-Wide: The employer did not provide safety data sheets to distributors and employers prior to or at the time of shipment of manufactured commercial chemicals, on or about, 3/6/19.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View DUX PAINT, LLC's full OSHA safety record →