Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRO TILE AND VINYL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRO TILE AND VINYL in BUILDING 247, FORT BELVOIR, VA 22060 (NAICS 238340). OSHA activity number 343829115.

Watch PRO Tile AND Vinyl — free Get an email when a new federal OSHA severe-injury report for PRO Tile AND Vinyl is published. One employer, no account, unsubscribe in one click.
Establishment
PRO TILE AND VINYL
Site address
BUILDING 247
City
FORT BELVOIR
State
VA
ZIP
22060
Mailing
7900 JOHN ADAMS COURT APT 101, ANNANDALE, VA 22003
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238340
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $1194.00 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.  a)    Building 247, Fort Belvoir, first floor: On or about 01/16/2019, the ground fault circuit interrupter (GFCI) used to supply power to a portable hand drill and wet saw was not used properly to protect a subcontractor employee from a potential electric shock hazard in that the GFCI was not plugged directly into a wall outlet.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1193.5
  • — Z (S) $1705

1926.404 F06

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:   a)    Building 247, Fort Belvoir, first floor: On or about 01/16/2019, the path to ground on the Dewalt wet saw was not permanent and continuous in that the ground prong was missing from the male attachment plug.      NOTE: 1926.302(a)(1) Electric power operated tools shall either be of the approved double-insulated type or grounded in accordance with Subpart K of this part.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.59)  a)    Building 247, Fort Belvoir, first floor: On or about 01/16/2019, the employer had not developed or implement a written hazard communication program for the chemical used in installing ceramic tile.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343829115.