Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JUSTIN CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JUSTIN CONSTRUCTION LLC in 546 WASHINGTON AVE, DUMONT, NJ 07628 (NAICS 238170). OSHA activity number 343836748.

Watch Justin Construction LLC — free Get an email when a new federal OSHA severe-injury report for Justin Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
546 WASHINGTON AVE
City
DUMONT
State
NJ
ZIP
07628
Mailing
105 GRACE STREET, IRVINGTON, NJ 07111
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.451 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:  A- Pump Jack Scaffold: Employees were engaged in siding work from a pump jack scaffold in which the supporting legs were positioned on icy conditions which were not provided a firm foundation.Condition noted on or about 03/08/2019
Recent events (1)
  • — Z (S) $3978

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  A- Pump Jack Scaffold: Employees engaged in siding work from a pump jack scaffold in which the  scaffold was not provided a means of fall protection exposing workers to fall hazards of approximately 18ft to the concrete below.Condition noted on or about 03/08/2019
Recent events (1)
  • — Z (S) $3978

1926.452 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  A- Pump Jack Scaffold: Employees engaged in siding work from a pump jack scaffold in which the pump jack scaffold was not provided triangular bracing at the base exposing workers to the potential for scaffold collapse or support kick out, Condition noted on or about 03/08/2019
Recent events (1)
  • — Z (S) $3978

1926.501 B01

Serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  A- Balcony: An employee engaged in carpentry work from an unprotected balcony edge in which a means of fall protection had not been utilized exposing the worker to fall hazards of 15ft to the concrete below. Condition noted on or about 03/08/2019  A- Balcony: An employee engaged in carpentry work from an unprotected balcony edge in which a means of fall protection had not been utilized exposed the worker to fall hazards of 15ft to the concrete below. Condition noted on or about 03/08/2019
Recent events (1)
  • — Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343836748.