Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: P & F BUILDERS INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of P & F BUILDERS INC. in 971 -975 BONNEL CT, UNION, NJ 07083 (NAICS 238130). OSHA activity number 343845822.

Watch P & F Builders INC. — free Get an email when a new federal OSHA severe-injury report for P & F Builders INC. is published. One employer, no account, unsubscribe in one click.
Establishment
P & F BUILDERS INC.
Site address
971 -975 BONNEL CT
City
UNION
State
NJ
ZIP
07083
Mailing
1053 PENNSYLVANIA AVE, LINDEN, NJ 07036
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.25 A

Serious Gravity 5 1 instance 10 exposed
Issued
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.25(a): Throughout this job site, during the course of construction operations, framing materials with nails, pipe and trash were lying in and adjacent to walkways and work areas, exposing employees to trip and fall hazards.  A) 971 Bonnel Ct Union, NJ 07083  Miscellaneous construction debris were scattered throughout the work area, which created slip trip, and fall hazards.    Hazard noted on or about 03/12/19
Recent events (1)
  • — Z (S) $2273

1926.56 A

Serious Gravity 5 1 instance 10 exposed
Issued
Penalty
Initial $3410.00 · Current $3410.00
29 CFR 1926.56(a): General. Construction areas, ramps, runways, corridors, offices, shops, and storage areas shall be lighted to not less than the minimum illumination intensities listed in Table D-3 while any work is in progress:      A) 971 Bonnel Ct Union, NJ 07083  The stairwell being used to access the upper working area was not illuminated exposing employees to trip and fall hazards.      Hazard observed on or about 03/12/19
Recent events (1)
  • — Z (S) $3410

1926.1052 B01

Serious Gravity 5 1 instance 10 exposed
Issued
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.1052(b)(1): Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.  A) 971 Bonnel Ct Union, NJ 07083  The stairwell being used to access the upper floors of the building were not temporarily fitted with wood or other solid material as required exposing employees to trip and fall hazards.   Hazard observed on or about 03/12/19
Recent events (1)
  • — Z (S) $2273

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):  A) 971 Bonnel Court, Union, NJ 07083  Employees were engaged in the process of staging floor trusses on the 3rd floor of the structure. The employees were standing on the upper wall plates used to frame interior and exterior walls, with no means of fall protection and exposed to fall hazards of approx. 36 ft.    Occurred on or about March 12, 2019
Recent events (1)
  • — Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343845822.