OSHA Inspection: ALLSOUTH ELECTRICAL, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALLSOUTH ELECTRICAL, LLC in 1260 SNOW POINT ROAD CHARLESTON NAVAL WEAPONS STATION, GOOSE CREEK, SC 29445 (NAICS 237130). OSHA activity number 343856894.

Watch Allsouth Electrical, LLC — free Get an email when a new federal OSHA severe-injury report for Allsouth Electrical, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1260 SNOW POINT ROAD CHARLESTON NAVAL WEAPONS STATION
City
GOOSE CREEK
State
SC
ZIP
29445
Mailing
PO BOX 40189, NORTH CHARLESTON, SC 29405
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
5
Ownership type
A

1 citation on file for this inspection.

1926.453 B02 VII

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2273.00 · Current $1250.00 Reduced
29 CFR 1926.453(b)(2)(vii): When outriggers were used, they were not positioned on pads or a solid surface as required.    a) East end of the jobsite: An Altec aerial lift mounted on a International Durastar model 4300 Chassis was used by employees to reach a transformer on an electrical pole. The outrigger plates were found sinking into the mud. No mudsills were used.