1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ALCOM, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALCOM, LLC in 501 EAST 52ND STREET NORTH, SIOUX FALLS, SD 57104 (NAICS 336212). OSHA activity number 343876496.

Watch Alcom, LLC — free Get an email when a new federal OSHA severe-injury report for Alcom, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ALCOM, LLC
Site address
501 EAST 52ND STREET NORTH
City
SIOUX FALLS
State
SD
ZIP
57104
Mailing
501 EAST 52ND STREET NORTH, SIOUX FALLS, SD 57104
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336212
Employees
70
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4959.00 · Current $3967.00 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operators and other employees from struck-by and laceration hazards during the use of a table saw:      (a)Alcom, LLC, at 501 East 52nd Street North, Sioux Falls, SD 57104: On or about and at times prior to March 20, 2019, the employer did not ensure employees were protected from struck-by hazards when operating the JET JPS-10TS table saw to cut both aluminum and wood in that the anti-kickback component of the guard was not installed. This condition exposed employees to struck-by hazards.
Recent events (2)
  • — I (O) $3967.2
  • — Z (S) $4959

1910.212 A03 II

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(3)(ii): Points of operation of machinery were not guarded to prevent employees from having any part of their body in the danger zone during operating cycles:     (a)Alcom, LLC, at 501 East 52nd Street North, Sioux Falls, SD 57104: On or about and at times prior to March 20, 2019, the employer did not ensure employees were protected from amputation hazards in that the front guard on the mechanical shear was not adjusted appropriately.  The opening between the work surface and the guard was greater than 0.625 inches with the point-of-operation being less than 6 inches from the face of the guard. This condition exposed employees to amputation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.219 E03 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(3)(i): Vertical or inclined belts were not enclosed by guards conforming to the requirements specified at 29 CFR 1910.219(m) and (o):    (a)Alcom, LLC, at 501 East 52nd Street North, Sioux Falls, SD 57104: On or about and at times prior to March 20, 2019, the employer did not ensure employees were protected from amputation hazards in that vertical belt on the west side of the shear did not completely enclose the belt and wheels creating an gap of 3-5 inches. This condition exposed employees to amputation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 A02 IX

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3720.00 · Current $2976.00 Reduced
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard:    (a)Alcom, LLC, at 501 East 52nd Street North, Sioux Falls, SD 57104: On or about and at times prior to March 20, 2019, the employer did not ensure employees were protected from laceration and shock hazards in that the operator's work stations fluorescent shop light, located approximately 6 feet above the ground, did not have a suitable fixture or lamp holder with a guard to prevent breakage. This condition exposed employees to laceration and shock hazards.
Recent events (2)
  • — I (S) $2976
  • — Z (S) $3720

1910.305 J01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(j)(1)(i): Rosettes and cleat-type lampholders and receptacles located less than 2.44 m (8 feet) above the floor had exposed terminals:  (a)Alcom, LLC, at 501 East 52nd Street North, Sioux Falls, SD 57104: on or about and at times prior to March 20, 2019, the employer did not ensure employees were protected from electrical hazards in that the operator's work stations fluorescent shop light, located approximately 6 feet above the ground, had exposed live pins. This condition exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

ALCOM, LLC

ALCOM, LLC

View ALCOM, LLC's full OSHA safety record →