Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: ADVANCE INDUSTRIAL MANUFACTURING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADVANCE INDUSTRIAL MANUFACTURING, INC. in 1996 LONGWOOD AVENUE, GROVE CITY, OH 43123 (NAICS 332312). OSHA activity number 343893459.

Watch Advance Industrial Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Advance Industrial Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1996 LONGWOOD AVENUE
City
GROVE CITY
State
OH
ZIP
43123
Mailing
1996 LONGWOOD AVENUE, GROVE CITY, OH 43123
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
35
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4959.00 · Current $3471.00 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.   On or about March 27, 2019, a Hyd-Mech model S-20 band saw was not guarded, in that the unused portion of the saw blade was not protected. Operators were exposed to contact hazards and increased risk for laceration during use, such as when cutting one and a half inch pipe for the handrail job.
Recent events (2)
  • — I (S) $3471.3
  • — Z (S) $4959

1910.132 D01 I

Other-than-serious 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:  29 CFR 1910.132(d)(1)(i): Select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment;  On or about March 27, 2019, the employer failed to select and require the use of PPE to protect employees from burns on the arms and torso related to welding activities. The employer did not select protective equipment and did not require protective equipment use for welding activities, such as but not limited to, above the shoulder and overhead position welding which involved increased risk of thermal burns from welding spatter during routine duties.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.132 F01 I

Other-than-serious 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(f): Training.   29 CFR 1910.132(f)(1): The employer shall provide training to each employee who is required by this section to use PPE. Each such employee shall be trained to know at least the following:  29 CFR 1910.132(f)(1)(i): When PPE is necessary;  On or about March 27, 2019, the employer failed to train when protective equipment use for the arms and torso was required during welding, such as but not limited to, during above the shoulder and overhead position welding which involved increased risk of thermal burns from welding spatter during routine duties.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 8870

29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:  29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure;  On or about March 27, 2019, the employer substituted multiple connected extension cords in lieu of fixed wiring in the building 2 production areas that occupied the west side of the building and areas near the Ficep CNC machine. Due to this condition, employees were at increased risk for electric shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ADVANCE INDUSTRIAL MANUFACTURING, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343893459.