GREENWOOD, DE —
OSHA Inspection: ENSINGER PENN FIBRE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ENSINGER PENN FIBRE, INC. in 221 S. CHURCH STREET CHURCH & SNIDER STREETS, GREENWOOD, DE 19950 (NAICS 326199). OSHA activity number 343900908.
Where did this inspection happen?
- Establishment
- ENSINGER PENN FIBRE, INC.
- Site address
- 221 S. CHURCH STREET CHURCH & SNIDER STREETS
- City
- GREENWOOD
- State
- DE
- ZIP
- 19950
- Mailing
- P.O. BOX 160, GREENWOOD, DE 19950
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 50
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $20845.00 · Current $10423.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) 221 S. Church Street, Greenwood, DE: On or about April 11, 2019, the employer failed to conduct a periodic inspection of energy control procedures at least annually. Employees perform servicing and maintenance activities on equipment including, but not limited to, punch presses, press brakes, extruders, slitters, CNC which had multiple energy sources including pneumatic, hydraulic, electric, and gravity. Abatement Note: a. Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.1910.147(c) (6)(i)(D) b. Where tagout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized and affected employee, of that employee's responsibilities under the energy control procedure being inspected, and the elements set forth in paragraph (c)(7)(ii) of this section.1910.147(c)(6)(ii) c. The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. Ensinger Penn Fibre was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(6)(I), which was contained in OSHA inspection number 1023288, citation number 2, item number 1 and was affirmed as a final order on (04/21/2015), with respect to a workplace located at Church & Snyder Streets, Greenwood, DE.
Recent events (2)
- — I (R) $10422.5
- — Z (R) $20845
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in DE
WILMINGTON, DE—2026-06-25
HATZEL AND BUEHLER, INC.
CAMDEN, DE—2026-06-24
VLC CONSTRUCTION LLC
MILFORD, DE—2026-06-18
PERDUE FARMS INCORPORATED
LINCOLN, DE—2026-06-18
FITZGERALD SALVAGE & RECYCLING
WILMINGTON, DE—2026-06-17
LC CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343900908.