Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARLO MASI SONS & DAUGHTER, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARLO MASI SONS & DAUGHTER, INC. in 9 WURZ AVE., UTICA, NY 13502 (NAICS 424480). OSHA activity number 343902029.

Watch Carlo Masi Sons & Daughter, INC. — free Get an email when a new federal OSHA severe-injury report for Carlo Masi Sons & Daughter, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9 WURZ AVE.
City
UTICA
State
NY
ZIP
13502
Mailing
9 WURZ AVE., UTICA, NY 13502
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424480
Employees
24
Ownership type
A

6 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2576.00 · Current $1546.00 Reduced
29 CFR 1910.22(d)(1): Walking-working surfaces were not inspected, regularly, and maintained in a safe condition.    a)  Ferris Bldg., loading dock, on or about 4/3/19:  The edge of the concrete loading dock that leads onto a fixed stairway was broken away and not maintained in a safe condition.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1545.6
  • — Z (S) $2576

1910.25 B03

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.25(b)(3): Uniform riser heights and tread depths were not provided between landings on stairs:  a)  Ferris Bldg., loading dock, on or about 4/3/19:  Stairway to loading dock did not have uniform riser height in that the risers measured 9 1/2", 8" and 9 1/2".  The ground level of the stairway landing was on a sloped surface and not parallel to the stairway.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.25 C03

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.25(c)(3):  The employer did not ensure standard stairs have a minimum tread depth of 9.5 inches (24 cm):  a)  Ferris Bldg., loading dock, on or about 4/3/19:  Stairs leading to the loading dock did not have a minimum tread depth of 9 1/2 inches in that the tread depth measured 7 1/4 inches.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2576.00 · Current $1546.00 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    (a)  Ferris Bldg., old cooler #6, on or about 4/3/19:  A 220 volt electrical outlet was not provided with a cover.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1545.6
  • — Z (S) $2576

1910.305 G02 III

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a)  Warehouse, Door #1, on or about 4/3/19:  Flexible cord providing current to a Master salamander portable heater was pulled loose from the fitting.  b)  Warehouse, Door #13, on or about 4/3/19:  Flexible cord providing current to a Master salamander portable heater was pulled loose from the fitting.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B03 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.28(b)(3)(ii): The employer did not ensure each employee is protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems:  a)  Ferris Bldg., on or about 4/3/19:  A floor hole measuring 4" X 3" was not covered.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343902029.