BUFFALO, NY —
OSHA Inspection: PC CONSTRUCTION SYSTEMS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PC CONSTRUCTION SYSTEMS INC. in 948 KENSINGTON AVENUE, BUFFALO, NY 14215 (NAICS 238160). OSHA activity number 343909958.
Where did this inspection happen?
- Establishment
- PC CONSTRUCTION SYSTEMS INC.
- Site address
- 948 KENSINGTON AVENUE
- City
- BUFFALO
- State
- NY
- ZIP
- 14215
- Mailing
- 1967 WEHRLE DRIVE SUITE 1-055, WILLIAMSVILLE, NY 14221
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $2273.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 4/4/19 at a roof project located at 948 Kensington Avenue, Buffalo, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1400
- — Z (S) $2273
1926.451 G01 I
- Issued
- Penalty
- Initial $3789.00 · Current $2325.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 4/4/19 at a roof project located at 948 Kensington Avenue, Buffalo, New York; employees performing roofing activities from a ladder jack scaffold approximately 18 feet high were not protected from falling by a personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2325
- — Z (S) $3789
1926.501 B11
- Issued
- Penalty
- Initial $3789.00 · Current $2325.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 4/4/19 at a roof project located at 948 Kensington Avenue, Buffalo, New York; employees were placing sheathing on the roof of a two story house. The roof had an 8 in 12 pitch and an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2325
- — Z (S) $3789
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343909958.