2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: RIVERDALE MILLS CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RIVERDALE MILLS CORPORATION in 130 RIVERDALE STREET, NORTHBRIDGE, MA 01534 (NAICS 332618). OSHA activity number 343911830.

Watch Riverdale Mills Corporation — free Get an email when a new federal OSHA severe-injury report for Riverdale Mills Corporation is published. One employer, no account, unsubscribe in one click.
Site address
130 RIVERDALE STREET
City
NORTHBRIDGE
State
MA
ZIP
01534
Mailing
130 RIVERDALE STREET, NORTHBRIDGE, MA 01534
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
148
Ownership type
A

11 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $11934.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Site: Building 1, at the Coating Line, on the catwalk above the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 a Coating Line Operator working from the catwalk did not utilize Energy Control Procedure RMC-021 for the control of potentially hazardous energy prior to commencing with activities covered by this subpart.  This included using his foot on the moving wire mesh in order to straighten it.  (b) Site: Building 1, at the Coating Line, at the Main Drive on the aisle side, 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 a Coating Line Operator did not utilize Energy Control Procedure RMC-021 for the control of potentially hazardous energy prior to commencing with activities covered by this subpart.  This included accessing the main drive area while the wire mesh was moving in order to straighten it.
Recent events (3)
  • — J (S) $0
  • — C (S) $11934
  • — Z (S) $11934

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8525.00 · Current $8525.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) Site: In Building 1, at the Coating Line, at the Big Spindle, 130 Riverdale Street, Northbridge, MA 01534: On 4/26/2019 the employer had not conducted a periodic inspection of Energy Control Procedure RMC-022 for the Big Spindle since 4/26/2016.
Recent events (3)
  • — 2 (S) $8525
  • — C (S) $8525
  • — Z (S) $8525

1910.147 C07 I A

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11934.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  (a) Site: Building 1, at the Coating Line, on the catwalk above the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 affected employees performed the duties of authorized employees when those employees performed tasks that required they remove or bypass guards in order to adjust moving wire mesh material.  (b)  Site: In Building 1, at the Coating Line, at the Main Drive on the aisle side, 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 affected employees performed the duties of authorized employees when those employees performed tasks that required they remove or bypass guards in order to adjust moving wire mesh material.
Recent events (3)
  • — J (S) $0
  • — C (S) $11934
  • — Z (S) $11934

1910.147 D

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11934.00 · Current $0.00 Reduced
29 CFR 1910.147(d): The application of energy control (lockout or tagout) actions were not done in the following sequence: (1) prepare for shutdown, (2) shut down machine or equipment, (3) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) affix lockout or tagout devices to each energy isolating device by authorized employee, (5) relieve, disconnect, restrain or otherwise render safe all stored or residual energy, (6) verify that isolation and deenergization of the machine or equipment have been accomplished:  (a) Site: Building 1, at the Coating Line, at the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 the application of energy control (lockout or tagout) actions were not done in the sequence prescribed by the standard in that none of the prescribed steps were performed.
Recent events (3)
  • — D (S) $0
  • — C (S) $11934
  • — Z (S) $11934

1910.147 D02

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $11934.00 · Current $0.00 Reduced
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  (a) Site: Building 1, at the Coating Line, on the catwalk above the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 a Coating Line Operator did not turn off or shut down the Main Drive using the procedures established for the machine or equipment prior to starting work covered by this subpart.  (b) Site: Building 1, at the Coating Line, at the Main Drive on the aisle side, 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 a Coating Line Operator did not turn off or shut down the Main Drive using the procedures established for the machine or equipment prior to starting work covered by this subpart.
Recent events (3)
  • — J (S) $0
  • — C (S) $11934
  • — Z (S) $11934

1910.147 D03

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $11934.00 · Current $0.00 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  (a) Site: Building 1, at the Coating Line, on the catwalk above the main drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 the energy isolating devices that were needed to control the energy to the Main Drive was not moved into the off position to isolate the machine or equipment from the energy source(s) prior to starting work covered by this subpart.   (b) Site: Building 1, at the Coating Line, at the Main Drive on the aisle side, 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 the energy isolating devices that were needed to control the energy to the Main Drive was not moved into the off position to isolate the machine or equipment from the energy source(s) prior to starting work covered by this subpart.
Recent events (3)
  • — J (S) $0
  • — C (S) $11934
  • — Z (S) $11934

1910.147 D04 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11934.00 · Current $0.00 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Site: At the Coating Line, 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 employees were engaged in activities requiring the use of Lockout/Tagout procedures and Lockout/Tagout devices were not affixed to energy isolating devices by employees prior to commencing with the work.
Recent events (3)
  • — J (S) $0
  • — C (S) $11934
  • — Z (S) $11934

1910.147 D06

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:  (a) Site: Building 1, at the Coating Line, on the catwalk above the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 prior to starting work on machines or equipment, the Coating Line Operator did not verify that isolation and deenergization of the Main Drive had been accomplished.   (b) Site: Building 1, at the Coating Line, at the Main Drive component on the aisle side, 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 prior to starting work on machines or equipment, the Coating Line Operator did not verify that isolation and deenergization of the Main Drive had been accomplished.
Recent events (3)
  • — D (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $11934.00 · Current $0.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Site: Building 1, at the Coating Line, on the catwalk above the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 a machine guard was not provided to protect a Coating Line Operator from moving parts of the Main Drive in that the operator periodically placed a foot through the railing on the catwalk and on to the moving wire mesh in order to straighten it.
Recent events (3)
  • — J (S) $0
  • — C (S) $11934
  • — Z (S) $11934

1910.212 A02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $11934.00 · Current $0.00 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:   (a) Site: In Building 1, On the Coating Line, At the aisle side of the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 the guard intended to prevent access to the point of operation on the Main Drive component was a hinged gate/door and could be easily circumvented due to the lack of a locking mechanism or other effective means to prevent unauthorized access.
Recent events (3)
  • — D (S) $0
  • — C (S) $11934
  • — Z (S) $11934

1910.219 C02 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $11934.00 · Current $0.00 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  (a) Site: In Building 1, On the Coating Line, At the aisle side of the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 the guard for the Main Drive had holes cut in it to allow the unprotected rotating shafts to protrude through the guard and pose hazards to Coating Line Operators.
Recent events (3)
  • — D (S) $0
  • — C (S) $11934
  • — Z (S) $11934

View RIVERDALE MILLS CORPORATION's full OSHA safety record →