OSHA Inspection: METROS BUILDERS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of METROS BUILDERS INC in 297 WEST UTICA ROAD, BUFFALO, NY 14222 (NAICS 236116). OSHA activity number 343945341.

Watch Metros Builders INC — free Get an email when a new federal OSHA severe-injury report for Metros Builders INC is published. One employer, no account, unsubscribe in one click.
Establishment
METROS BUILDERS INC
Site address
297 WEST UTICA ROAD
City
BUFFALO
State
NY
ZIP
14222
Mailing
1643 ORCHARD PARK ROAD, WEST SENECA, NY 14224
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.150 C01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1232.00 · Current $800.00 Reduced
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof:     a) On or about 4/17/19, at the site of Buffalo, NY. Fire extinguishers were not provided for the entire wood frame 3-story building of 4,000 square feet each floor.     NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $800
  • — Z (S) $1232

1926.405 A02 II E

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1232.00 · Current $800.00 Reduced
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:     a) On or about 4/17/19, at the first floor area of the site, Buffalo, NY. Up to ten temporary lamps, as low as 7 feet from the ground, lacked the protection cage to prevent accidental contact.     NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $800
  • — Z (S) $1232

1926.405 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(b)(1): Openings in boxes, cabinets, and fittings through which conductors entered were not effectively closed:   a) On or about 4/17/19, at the first floor area of the site, Buffalo, NY. Circuit breakers, in the temporary panel, had a gap between panel cover and conductors that allowed the fingers to go through. Openings were not effectively closed.   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343945341.