Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PINICAS SIDING AND ROOFING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PINICAS SIDING AND ROOFING, LLC in W139 N6157 WEYER HAVEN DRIVE, MENOMONEE FALLS, WI 53051 (NAICS 238160). OSHA activity number 343959169.

Watch Pinicas Siding AND Roofing, LLC — free Get an email when a new federal OSHA severe-injury report for Pinicas Siding AND Roofing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
W139 N6157 WEYER HAVEN DRIVE
City
MENOMONEE FALLS
State
WI
ZIP
53051
Mailing
3548 S. 45TH ST., GREENFIELD, WI 53220
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

8 citations on file for this inspection.

1903.19 D01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $325.00 · Current $325.00
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.  (a)  The employer failed to provide documentation to the Agency demonstrating that abatement is completed for the serious violations that were issued by the Agency.
Recent events (1)
  • — Z (O) $325

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1875.00 · Current $937.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    (a) On or about April 22, 2019, the employer did not ensure that employees exposed to overhead hazards were protected from falling or flying objects from above by a protective helmet.
Recent events (2)
  • — I (S) $937
  • — Z (S) $1875

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2500.00 · Current $1250.00 Reduced
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.    (a) On or about April 22, 2019, the employer did not ensure that employees installing siding with a pneumatic nail gun were wearing eye protection, thereby exposing employees to eye injuries from flying particles.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2500

1926.451 A06

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3751.00 · Current $3751.00
29 CFR 1926.451(a)(6): Scaffolds were not constructed in accordance with the design by a qualified person:    (a) On or about April 22, 2019, at the construction site located at W139N6157 Weyerhaven Dr, Menomonee Falls, WI 53051, the ladder jack scaffold was not constructed in accordance with the design of that system. This exposed employee to fall hazards.
Recent events (2)
  • — I (S) $3751
  • — Z (S) $3751

1926.454 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3751.00 · Current $0.00 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.    (a) On or about April 22, 2019, at the construction site located at W139N6157 Weyerhaven Dr, Menomonee Falls, WI 53051, employees who utilized a ladder jack scaffold to install siding on a residential building were not properly trained to recognize and minimize hazards from working on a scaffold system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3751

1926.454 B

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3751.00 · Current $0.00 Reduced
29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. The training shall include 1-4 of this section:    (a) On or about April 22, 2019, at the construction site located at W139N6157 Weyerhaven Dr, Menomonee Falls, WI 53051, employees who erected a ladder jack scaffold to install siding on a residential building were not properly trained by a competent person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3751

1926.451 G01 I

Repeat Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $7502.00 · Current $3751.00 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:    a.   On or about April 22, 2019, at the construction site located at W139N6157 Weyerhaven Dr, Menomonee Falls, WI 53051, an employee was exposed to a fall hazard of approximately 13 3/10 feet on a ladder jack scaffold.    Pinicas Siding & Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(g)(1)(I), which was contained in OSHA inspection number 980191, citation number 2, item number 1, group letter a,  and was affirmed as a final order on 11/14/14, with respect to a workplace located at N44W22925 Beach St., Pewaukee WI 53072.
Recent events (2)
  • — I (R) $3751
  • — Z (R) $7502

1926.503 C03

Repeat Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7502.00 · Current $0.00 Reduced
29 CFR 1926.503(c)(3):  When inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill, the employer shall retrain the affected employee.    (a) On or about April 22, 2019, at the construction site located at W139N6157 Weyerhaven Dr, Menomonee Falls, WI 53051, an employee was exposed to a fall hazard of approximately 13 3/10 feet. The employer did not ensure that an employee retained the understanding or ability to recognize fall hazards and implement correct fall protection methods.    Pinicas Siding & Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.503(c)(3), which was contained in OSHA inspection number 1153923, citation number 1, item number 1 and was affirmed as a final order on 7/13/16, with respect to a workplace located at 3054 Superior Rd, Milwaukee WI 53207.
Recent events (2)
  • — I (R) $0
  • — Z (R) $7502