1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PREGIS INNOVATIVE PACKAGING LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PREGIS INNOVATIVE PACKAGING LLC in 300 LOWER WARREN ST., QUEENSBURY, NY 12804 (NAICS 326150). OSHA activity number 343999348.

Watch Pregis Innovative Packaging LLC — free Get an email when a new federal OSHA severe-injury report for Pregis Innovative Packaging LLC is published. One employer, no account, unsubscribe in one click.
Site address
300 LOWER WARREN ST.
City
QUEENSBURY
State
NY
ZIP
12804
Mailing
300 LOWER WARREN ST., QUEENSBURY, NY 12804
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326150
Employees
1900
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11366.00 · Current $6819.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      a) COEX Extrusion Line Area - On or about April 5, 2019, employees were exposed to caught-in hazards due to not utilizing lockout/tagout procedures for the Line 52, COEX Line that consisted of multiple energy sources of electric, air, and water.
Recent events (2)
  • — I (S) $6819
  • — Z (S) $11366

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Facility - On or about August 1, 2019, the employer did not conduct a periodic inspection within the last 12 months for performing servicing and/or maintenance work on the Line 52 Winder.  The last periodic inspection was performed on 2/23/18.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Other-than-serious 1 instance 100 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Facility Entrance - On or prior to May 10, 2019, a relocatable power tap (RPT) or power strip was not installed and used in accordance with instruction in the listing, labeling, or certification such as, but not limited to, the RPT being zip-tied and permanently secured to electrical conduit used as a substitute for fixed wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 100 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Facility - On or prior to May 10, 2019, an extension cord powering two fans was being used as a substitute for fixed wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PREGIS INNOVATIVE PACKAGING LLC's full OSHA safety record →