Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MES WAYLAND ASSISTED LIVING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MES WAYLAND ASSISTED LIVING, LLC in 10 GREEN WAY, WAYLAND, MA 01778 (NAICS 623312). OSHA activity number 344004296.

Watch MES Wayland Assisted Living, LLC — free Get an email when a new federal OSHA severe-injury report for MES Wayland Assisted Living, LLC is published. One employer, no account, unsubscribe in one click.
Site address
10 GREEN WAY
City
WAYLAND
State
MA
ZIP
01778
Mailing
10 GREEN WAY, WAYLAND, MA 01778
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623312
Employees
75
Ownership type
A

4 citations on file for this inspection.

1910.151 C

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5683.00 · Current $1500.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    Location: Facility    On or about April 30, 2019, a drenching facility was not provided for quick and/or immediate use to employees that utilize disinfectant chemicals such as but not limited to; Virex TB Ready-To-Use disinfectant cleaner and Peroxide multi surface cleaner and disinfectant.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $5683

1910.1200 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $4831.00 · Current $2000.00 Reduced
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use;    Location: Facility    On or about April 30, 2019, safety data sheets were not kept in the workplace, for but not limited to, Virex TB Ready-To-Use disinfectant cleaner and Peroxide multi surface cleaner and disinfectant.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4831

1910.1200 H01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Location: Facility  On or about April 30, 2019, employees were not effectively trained on hazardous chemicals in their work area when working with but not limited to, Virex TB Ready-To-Use disinfectant cleaner and Peroxide multi surface cleaner and disinfectant.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 A02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $8051.00 · Current $2500.00 Reduced
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners:    Location: Kitchen    On or about April 30, 2019, employees were exposed to fire hazards and electric shock hazards from an extension cord being used as permanent wiring to supply power to a portable microwave.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $8051

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344004296.