HAINES CITY, FL —
OSHA Inspection: WALSDORF METAL WORKS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WALSDORF METAL WORKS, LLC in 96 US HIGHWAY 17/92 N., HAINES CITY, FL 33844 (NAICS 332312). OSHA activity number 344043617.
Where did this inspection happen?
- Establishment
- WALSDORF METAL WORKS, LLC
- Site address
- 96 US HIGHWAY 17/92 N.
- City
- HAINES CITY
- State
- FL
- ZIP
- 33844
- Mailing
- P.O. BOX 1059, DAVENPORT, FL 33837
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 11
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.101 B
- Issued
- Abate by
- Penalty
- Initial $3031.00 · Current $1819.00 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) On or about 05/30/2019, at the storage area for compressed gas cylinders in the fabrication shop: 1) Compressed gases of different types were stored together at the same location. 2) There were no signs posted indicating the identity of the substance and the hazard associated with flammable compressed gas cylinders being stored. 3) Compressed gas cylinders in storage were missing protective caps. b) On or about 05/30/2019, at the fabrication shop, an argon compressed gas cylinders was not properly secured to prevent for being knocked over.
Recent events (2)
- — I (S) $1818.6
- — Z (S) $3031
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $5304.00 · Current $3182.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) On or about May 30, 2019, employees were exposed to crushing and/or amputation injuries when bending aluminum metal while operating the Accupress Advantage 725012 without a guarding method. b) On or about May 30, 2019, employees were exposed to lacerations and/or amputation injuries when cutting aluminum metal while operating the Accurshear 625012 with a section of the guard missing.
Recent events (2)
- — I (S) $3182.4
- — Z (S) $5304
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) On or about May 30, 2019, at the fabrication shop, employees performing cleaning, clearing jams or setting up Accurpress 725012 and Accurshear 625012 were exposed to caught in, caught in between and struck by hazards, in that the employer did not have a hazardous energy control program.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.334 A02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) On or about May 30, 2019, at fabrication, employees were using a powered hand grinder, polisher and sander with a damaged cord that had visible internal wiring exposed. b) On or about May 30, 2019, at fabrication, employees were using an extension cord to power different hand tool equipment where the outer cover was pulled from the strain relief, exposing wires near the plug connector. c) On or about May 30, 2019, at fabrication, employees were using a damaged extension cord to power portable equipment where the outer cover was split open exposing wiring near the plug.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source