STREAMWOOD, IL —
OSHA Inspection: ALUMINUM COIL ANODIZING CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALUMINUM COIL ANODIZING CORPORATION in 501 E. LAKE STREET, STREAMWOOD, IL 60107 (NAICS 332813). OSHA activity number 344045521.
Where did this inspection happen?
- Establishment
- ALUMINUM COIL ANODIZING CORPORATION
- Site address
- 501 E. LAKE STREET
- City
- STREAMWOOD
- State
- IL
- ZIP
- 60107
- Mailing
- 501 E. LAKE STREET, STREAMWOOD, IL 60107
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 60
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.146 C01
- Issued
- Abate by
- Penalty
- Initial $5304.00 · Current $2917.00 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces. (a) Anodizing Department- On or about May 16, 2019, the employer did not identify the Bright Dip Tank # 7, containing nitric and phosphoric acid as a as a permit required confined space. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2917.2
- — Z (S) $5304
1910.146 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: (a) Facility Wide - On or about May 16, 2019, the employer did not ensure that a danger sign was posted on the permit confined spaces such as but not limited to Bright Dip Tank # 7 to inform employees of the existence, location and the danger posed by the permit space. The signs posted read caution confined space. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 C07 II
- Issued
- Abate by
- Penalty
- Initial $5304.00 · Current $2917.00 Reduced
General-duty citation text
29 CFR 1910.146(c)(7)(ii): When it was necessary to enter the permit space to eliminate hazards, such entry was not performed under 29 CFR 1910.146(d) through 29 CFR 1910.146(k) (a) Anodizing Department - On or about May 16, 2019, the employer did not ensure that when it was necessary to enter the Bright Dip Tank 7 to eliminate the hazard, the entry was performed under 1910.146(d)- (k). The employees entered the bright dip tank to test the Ph in order to determine that it was safe to enter. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2917.2
- — Z (S) $5304
1910.146 C07 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(c)(7)(iii): The employer did not document the basis for determining that all hazards in a permit space had been eliminated, through a written certification that contained the date, the location of the space, and the signature of the person making the determination. (a) Anodizing Department - On or about May 16, 2019, the employer did not document that all hazards were eliminated through a written certification that contained the signature of the person making that determination, prior to entering the Bright Dip Tank #7 to replace screws and bolts on the roller. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 G04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(g)(4): The employer did not certify that the training required by 29 CFR 1910.146(g)(1) through 29 CFR 1910.146(g)(3) had been accomplished: (a) Facility Wide - On or about May 16, 2019, the employer did not certify that permit required confined space training was provided to employees, who entered permit confined spaces. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $5304.00 · Current $2917.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) Facility Wide - On May 30, 2019, the employer failed to ensure that periodic inspections of the energy control procedures were performed and contained the required documentation such as the identification of the machine or equipment, inspection date, employees included and the person performing the inspection. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2917.2
- — Z (S) $5304
1910.147 F03 II D
- Issued
- Abate by
- Penalty
- Initial $5304.00 · Current $2917.00 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: (a) Anodizing Department - On or about May 20, 2019, the employer failed to ensure that each authorized employee affixed a personal lockout device before working on equipment. Each maintenance employee(s) performing work inside Bright Dip Tank # 7 did not affix a personal lockout device while replacing a roller screw hardware prior to performing the work. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2917.2
- — Z (S) $5304
More inspections at ALUMINUM COIL ANODIZING CORPORATION
STREAMWOOD, IL—2025-01-15
ALUMINUM COIL ANODIZING CORPORATION
STREAMWOOD, IL—2021-05-05 00:00:00
ALUMINUM COIL ANODIZING CORPORATION
STREAMWOOD, IL—2021-03-16 00:00:00
ALUMINUM COIL ANODIZING CORPORATION
STREAMWOOD, IL—2019-05-13 00:00:00
ALUMINUM COIL ANODIZING CORPORATION
STREAMWOOD, IL—2009-11-04 00:00:00
ALUMINUM COIL ANODIZING CORPORATION
View ALUMINUM COIL ANODIZING CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 332813)
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
WARSAW, IN—2026-07-08
SURFACE ENHANCEMENTS
KENT, WA—2026-07-06
WA317991930 - HYTEK FINISHES CO
PHOENIX, AZ—2026-06-24
CPX2026XTP177X0010 - FRONTIER GROUP, INC.
MELROSE PARK, IL—2026-06-24
NATIONAL PLATING SOLUTIONS LLC DBA SOMERVILLE PLATING
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source