Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EAGLE SUSPENSIONS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of EAGLE SUSPENSIONS, INC. in 1811 W. ARKANSAS STREET, DURANT, OK 74701 (NAICS 332611). OSHA activity number 344056098.

Watch Eagle Suspensions, INC. — free Get an email when a new federal OSHA severe-injury report for Eagle Suspensions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1811 W. ARKANSAS STREET
City
DURANT
State
OK
ZIP
74701
Mailing
1811 W. ARKANSAS STREET, DURANT, OK 74701
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332611
Employees
183
Ownership type
A

3 citations on file for this inspection.

1910.147 C04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $10229.00 · Current $6137.00 Reduced
29 CFR 1910.147(c)(4): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  On or about May 29, 2019, the employer did not ensure lockout/tagout procedures were utilized when employees were engaged in adjusting a taper press die at the point of operation.  This exposed the employee(s) caught-in hazards.
Recent events (2)
  • — I (S) $6137.4
  • — Z (S) $10229

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.   On or about May 29, 2019, the employer did not ensure an employee received authorized lockout-tagout training prior to allowing the employee to engage in adjusting a taper press die at the point of operation.  This exposed the employee to caught-in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees.  On or about May 29, 2019, the employer did not ensure lockout-tagout devices were in place prior to allowing an employee to engage in adjusting a taper press die at the point of operation.  This exposed the employee to caught-in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344056098.