Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION ESCALATOR PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRECISION ESCALATOR PRODUCTS, INC. in 147 N. MICHIGAN AVE., KENILWORTH, NJ 07033 (NAICS 332710). OSHA activity number 344059019.

Watch Precision Escalator Products, INC. — free Get an email when a new federal OSHA severe-injury report for Precision Escalator Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
147 N. MICHIGAN AVE.
City
KENILWORTH
State
NJ
ZIP
07033
Mailing
147 N. MICHIGAN AVE., KENILWORTH, NJ 07033
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
98
Ownership type
A

3 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 1 instance 98 exposed
Issued
Penalty
Initial $3978.00 · Current $2984.00 Reduced
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route.   a)Precision Escalator Products, Inc./147 North Michigan Ave/Kenilworth, NJ 07033 - Metal Storage Room: The fire exit routes in the back of the metal storage room was blocked by materials and equipment creating a tripping hazard in the route to the emergency exit door.  Condition observed on or about 6/6/2019.
Recent events (3)
  • — J (S) $2983.5
  • — C (S) $3978
  • — Z (S) $3978

1910.179 L03 III

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $3978.00 · Current $2984.00 Reduced
29 CFR 1910.179(l)(3)(iii): The employer did not ensure that repairs or replacements of crane hooks were provided promptly as needed for safe operation.  a)Precision Escalator Products, Inc./147 North Michigan Ave/Kenilworth, NJ 07033 /Robbins & Myers 3-Ton Hoist Bridge Crane: A missing safety locking device on the crane hook was not replaced or repaired before use, exposing employees to struck-by hazards.   Condition observed on or about 6/6/2019.
Recent events (3)
  • — J (S) $2983.5
  • — C (S) $3978
  • — Z (S) $3978

1910.303 G01 II

Deleted Serious Gravity 1 1 instance 98 exposed
Issued
Penalty
Initial $3978.00 · Current $0.00 Reduced
29 CFR 1910.303(g)(1)(ii): Working spaces with electrical equipment rated 600 volts, nominal, or less was used for storage:  a) Precision Escalator Products, Inc./147 North Michigan Ave/Kenilworth, NJ 07033 - In Assembly Area & Metal Storage Room: Electrical Disconnect area(s) were used for storage of miscellaneous materials.                       Condition observed on or about 6/6/2019.
Recent events (3)
  • — J (S) $0
  • — C (S) $3978
  • — Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344059019.