POINTS, WV —
OSHA Inspection: YODER & SONS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of YODER & SONS, LLC in 1693 SLANESVILLE PIKE, POINTS, WV 25437 (NAICS 321920). OSHA activity number 344062732.
Where did this inspection happen?
- Establishment
- YODER & SONS, LLC
- Site address
- 1693 SLANESVILLE PIKE
- City
- POINTS
- State
- WV
- ZIP
- 25437
- Mailing
- 1693 SLANESVILLE PIKE, POINTS, WV 25437
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 14
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $3789.00 · Current $2273.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: (a) Pallet Shop: On June 5, 2019 and times prior, the employer has not developed a specific energy control procedure for the Keystone chop saw for employees that conduct servicing and maintenance, such as blade changes. The Keystone chop saw has multiple energy sources, 480 volt electrical and 120 psi pneumatic pressure. (b) Pallet Shop: On June 5, 2019 and times prior, the employer has not developed a specific energy control procedure for the Keystone gang saw for employees that conduct servicing and maintenance, such as blade changes. The Keystone chop saw has multiple energy sources, 440 volt electrical and 120 psi pneumatic pressure.
Recent events (2)
- — I (S) $2273.4
- — Z (S) $3789
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: (a) Pallet Shop: On June 5, 2019 and times prior, the employer did not conduct an annual periodic inspection between an inspector and authorized employee to ensure that the employee(s) followed the energy control procedures for the Keystone chop saw which has multiple energy sources; 480 volt electrical and 120 psi pneumatic pressure. (b) Pallet Shop: On June 5, 2019 and times prior, the employer did not conduct an annual periodic inspection between an inspector and authorized employee to ensure that the employee(s) followed the energy control procedures for the Keystone gang saw which has multiple energy sources; 440 volt electrical and 120 psi pneumatic pressure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Pallet Shop: On June 5, 2019 and times prior, the employer did not provide training to employees that were authorized to conduct servicing and maintenance activities, such as blade changes, on the Keystone chop saw. (b) Pallet Shop: On June 5, 2019 and times prior, the employer did not provide training to employees that were authorized to conduct servicing and maintenance activities, such as blade changes, on the Keystone gang saw.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Pallet Shop: On June 5, 2019 and times prior, the employer did not ensure that lockout devices were applied to the electrical disconnect (480 volt) and pneumatic pressure on the Keystone chop saw by the authorized employee during maintenance and servicing such as, changing the blade. (b) Pallet Shop: On June 5, 2019 and times prior, the employer did not ensure that lockout devices were applied to the electrical disconnect (440 volt) and pneumatic pressure on the Keystone gang saw by the authorized employee during maintenance and servicing such as, changing the blade.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3789.00 · Current $2273.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Pallet Shop: On June 5, 2009 and times prior, the employer did not ensure that machine guarding was provided on the Keystone chop saw to prevent employees contacting the bottom portion of the 20 inch circular blade during operation.
Recent events (2)
- — I (S) $2273.4
- — Z (S) $3789
More inspections in this industry (NAICS 321920)
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
CLANTON, AL—2026-07-14
SPECWOOD PRODUCTS, INC.
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
WASHINGTON COURT HOUSE, OH—2026-07-09
HALLIDAY LUMBER, LLC
More inspections in WV
CHARLESTON, WV—2026-07-15
ASTECH CORPORATION
PARKERSBURG, WV—2026-07-15
UNKNOWN
VIENNA, WV—2026-07-15
PHOENIX ASSOCIATES, INC.
BRIDGEPORT, WV—2026-07-14
MID ATLANTIC METALWORKS INC.
BRIDGEPORT, WV—2026-07-14
INFINITY ELECTRIC & SERVICE COMPANY, LLC
Source