Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: HUMBERTO TELLEZ DBA TELLEZ CARPENTRY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HUMBERTO TELLEZ DBA TELLEZ CARPENTRY in 3800 COUNTRYSIDE LANE, GLENVIEW, IL 60025 (NAICS 238130). OSHA activity number 344063110.

Watch Humberto Tellez DBA Tellez Carpentry — free Get an email when a new federal OSHA severe-injury report for Humberto Tellez DBA Tellez Carpentry is published. One employer, no account, unsubscribe in one click.
Site address
3800 COUNTRYSIDE LANE
City
GLENVIEW
State
IL
ZIP
60025
Mailing
4909 W. 28TH STREET, CICERO, IL 60804
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

9 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $311.00 · Current $311.00
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   M & J Construction Service, Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number            Item Number                    Abatement Date   02                                01                                   09/04/2019 03                                01                                   09/04/2019   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $311

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1932.00 · Current $1932.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):       a) On or about June 7, 2019, employees were exposed to the hazard of falling approximately 8 feet to the basement while walking/working at an unprotected edge on the main level of the building.         No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $1932

1926.100 A

Serious Gravity 5 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $1932.00 · Current $1932.00
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:         a) On or about June 7, 2019, employees were exposed to head injury while working without protective helmets in areas below carpentry operations.        No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $1932

1926.403 I02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1932.00 · Current $1932.00
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:   a) on or about June 7, 2019, a 120 volt outlet/junction box in the front room of the building on the main level was not guarded or otherwise protected to prevent accidental contact with energized electrical parts.   No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $1932

1926.404 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:    a) On or about June 7, 2019, employees were provided with electrical tools and equipment connected by temporary extension cords without the use of an assured equipment grounding program or ground fault circuit interrupters (GFCI).    No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $0

1926.416 E01

Serious Gravity 5 4 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:      a) On or about June 7, 2019, worn and frayed electrical cords were used to supply electricity to tools and equipment at the site.   No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $0

1926.416 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2898.00 · Current $2898.00
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:           a) On or about June 7, 2019, employees were exposed to electrical hazards where carpentry work was conducted adjacent to an energized electrical service drop.           No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $2898

1926.1053 B12

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side-rails:      a) On or about June 7, 2019, a portable aluminum extension ladder was provided for employee use where the ladder or the employees could contact an electrical service drop power line.       No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $0

1926.503 B01

Other-than-serious 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record:        a) On or about June 7, 2019, the employer did not prepare written certification records related to employee fall protection training.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344063110.