MILFORD, MA —
OSHA Inspection: JOHN GULIANO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOHN GULIANO in 51 EXCHANGE ST, MILFORD, MA 01757 (NAICS 238170). OSHA activity number 344066212.
Where did this inspection happen?
- Establishment
- JOHN GULIANO
- Site address
- 51 EXCHANGE ST
- City
- MILFORD
- State
- MA
- ZIP
- 01757
- Mailing
- 13 READE ST, MILFORD, MA 01757
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.252 A
- Issued
- Abate by
- Penalty
- Initial $2273.00 · Current $1137.00 Reduced
General-duty citation text
29 CFR 1926.252(a): Whenever materials are dropped more than 20 feet to any point lying outside the exterior walls of the building, an enclosed chute of wood, or equivalent material, was not used: a) 51 Exchange St., Milford, MA: On or about June 4, 2019, employees were observed throwing building debris from the scaffold in use at this address, which was in excess of 25 feet above the ground below.
Recent events (2)
- — I (S) $1136.5
- — Z (S) $2273
1926.451 F06
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $1421.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, and/or moved such that they or any conductive material handled on them was closer than 10 feet to an exposed energized power line of less than 300 volts. a) 51 Exchange St., Milford, MA: On or about June 4, 2019, two employees were observed using a pump jack scaffold whose conductive parts were less than 6 feet from the energized uninsulated house electrical service drop lines.
Recent events (2)
- — I (S) $1421
- — Z (S) $2842
1926.1053 B12
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders did not have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment: a) 51 Exchange St., Milford, MA: On or about June 4, 2019, employees were observed working from a pump jack scaffold system where their means of access to the scaffold working level was an aluminum extension ladder which was set up less than 6 feet from the house electrical service drop lines.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: a) 51 Exchange St., Milford, MA: On or about June 4, 2019, 2 employees were observed working on a pump jack scaffold that was not secured to the structure at its bottom.
Recent events (2)
- — I (O) $0
- — Z (S) $2842
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344066212.