Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOHN GULIANO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOHN GULIANO in 51 EXCHANGE ST, MILFORD, MA 01757 (NAICS 238170). OSHA activity number 344066212.

Watch John Guliano — free Get an email when a new federal OSHA severe-injury report for John Guliano is published. One employer, no account, unsubscribe in one click.
Establishment
JOHN GULIANO
Site address
51 EXCHANGE ST
City
MILFORD
State
MA
ZIP
01757
Mailing
13 READE ST, MILFORD, MA 01757
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.252 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1137.00 Reduced
29 CFR 1926.252(a): Whenever materials are dropped more than 20 feet to any point lying outside the exterior walls of the building, an enclosed chute of wood, or equivalent material, was not used:     a) 51 Exchange St., Milford, MA: On or about June 4, 2019, employees were observed throwing building debris from the scaffold in use at this address, which was in excess of 25 feet above the ground below.
Recent events (2)
  • — I (S) $1136.5
  • — Z (S) $2273

1926.451 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $1421.00 Reduced
29 CFR 1926.451(f)(6):  Scaffolds were erected, used, dismantled, altered, and/or moved such that they or any conductive material handled on them was closer than 10 feet to an exposed energized power line of less than 300 volts.     a) 51 Exchange St., Milford, MA: On or about June 4, 2019, two employees were observed using a pump jack scaffold whose conductive parts were less than 6 feet from the energized uninsulated house electrical service drop lines.
Recent events (2)
  • — I (S) $1421
  • — Z (S) $2842

1926.1053 B12

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(12): Ladders did not have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment:    a) 51 Exchange St., Milford, MA: On or about June 4, 2019, employees were observed working from a pump jack scaffold system where their means of access to the scaffold working level was an aluminum extension ladder which was set up less than 6 feet from the house electrical service drop lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $0.00 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:    a) 51 Exchange St., Milford, MA: On or about June 4, 2019, 2 employees were observed working on a pump jack scaffold that was not secured to the structure at its bottom.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2842

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344066212.