Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRESTIGE HOME BUILDER INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRESTIGE HOME BUILDER INC. in 1654 84TH STREET, BROOKLYN, NY 11214 (NAICS 236117). OSHA activity number 344073283.

Watch Prestige Home Builder INC. — free Get an email when a new federal OSHA severe-injury report for Prestige Home Builder INC. is published. One employer, no account, unsubscribe in one click.
Site address
1654 84TH STREET
City
BROOKLYN
State
NY
ZIP
11214
Mailing
10-03 141ST STREET, WHITESTONE, NY 11357
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236117
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.  Location: 1654 84th Street, Brooklyn, NY; Ground floor  On or about 6/11/2019,  a) A relocatable power taps rated for household use only was being used by employees in a construction site to power lighting equipment.
Recent events (1)
  • — Z (S) $2273

1926.403 I02 I

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.     Location: 1654 84th Street, Brooklyn, NY; Ground floor  On or about 6/11/2019,   a) Two breaker panel were not installed with the dead front covers.  Live electrical parts were exposed to accidental contact.
Recent events (1)
  • — Z (S) $3978

1926.405 G02 III

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:  Location: 1654 84th Street, Brooklyn, NY; Ground floor  On or about 6/11/2019,  a) The conductors of a flexible cord for the temporary lights were with splices.  The splices were covered with twist-on lock nuts only.
Recent events (1)
  • — Z (S) $2842

1926.1052 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan.   Location: 1654 84th Street, Brooklyn, NY; Ground floor  On or about 6/11/2019,   a) The treads and landings of the pan stairs were not filled or fitted with any solid material to the top edge of each pan.  Employees used these stairs to travel between floors.
Recent events (1)
  • — Z (S) $2273

1926.1052 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge.  Location: 1654 84th Street, Brooklyn, NY.  On or about 6/11/2019,   a) The stairways between each and every floor were not installed with handrails.
Recent events (1)
  • — Z (S) $2273

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344073283.