Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRO ROOF SOLUTIONS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRO ROOF SOLUTIONS LLC in 215 NAVARRE RD SW, CANTON, OH 44718 (NAICS 238160). OSHA activity number 344099346.

Watch PRO Roof Solutions LLC — free Get an email when a new federal OSHA severe-injury report for PRO Roof Solutions LLC is published. One employer, no account, unsubscribe in one click.
Site address
215 NAVARRE RD SW
City
CANTON
State
OH
ZIP
44718
Mailing
6098 AVON RD, CARROLLTON, OH 44615
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.   On or about May 24, 2019, during the removal and installation of roofing material at a job site located at 215 Navarre Rd SW, Canton, Ohio 44718; the employer did not ensure employees working on the roof of an existing commercial location were protected from a fall of approximately 16.8 feet by utilizing a fall protection system.
Recent events (1)
  • — Z (S) $3978

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   On or about May 24, 2019 at the job site located at 215 Navarre Rd SW, Canton, Ohio 44718; during the removal and installation of roofing material on a commercial roof, the employer did not ensure portable ladders extend 3 feet above the upper landing surface.
Recent events (1)
  • — Z (S) $3978