Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CEDARLINE WOODWORKS/DOVE PROPERTIES LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CEDARLINE WOODWORKS/DOVE PROPERTIES LLC in 320 W. MOSES, CUSHING, OK 74023 (NAICS 337110). OSHA activity number 344099759.

Watch Cedarline Woodworks/Dove Properties LLC — free Get an email when a new federal OSHA severe-injury report for Cedarline Woodworks/Dove Properties LLC is published. One employer, no account, unsubscribe in one click.
Site address
320 W. MOSES
City
CUSHING
State
OK
ZIP
74023
Mailing
320 W. MOSES, CUSHING, OK 74023
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
2
Ownership type
A

3 citations on file for this inspection.

1910.213 C01

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  On or about June 20, 2019, and at times prior there to, circular handfed ripsaws operated by employees were not adequately guarding to protect employees from flying debris, rotating parts, and the point of operation.  Employees were exposed to struck-by and amputation hazards while operating equipment including but not limited to the following instances:    A. Grizzly 12" Table Saw B. Delta 10" Tilting Arbor Saw
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.213 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(g)(1): Each swing cutoff saw was not provided with a hood that completely enclosed the upper half of the saw, the arbor end, and the point of operation at all positions of the saw:  On or about June 20, 2019, and at times prior there to, employees operated a swing cutoff saw that was not adequately guarded to protect them from flying debris, rotating parts, and the point of operation (bottom of blade).  Employees were exposed to struck-by and amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 A02 II

Other-than-serious 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(a)(2)(ii): Temporary wiring was not removed immediately upon completion of the project or purpose for which the wiring was installed:    On or about June 20, 2019, and at times prior there to, temporary wiring (extension cords) were used as permanent wiring including but not limited to the following instances, exposing employees to electric shock hazards:  A. Orange extension cord near front door entrance of cabinet shop powering the Dewalt 12 inch Miter Saw. B. Yellow extension cord in the middle of the cabinet shop powering the Grizzly 12 inch Table Saw.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344099759.