WHITEHOUSE, TX —
OSHA Inspection: CHRIS CLAY CONSTRUCTION, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHRIS CLAY CONSTRUCTION, LLC in 17730 SOUTH POINT ROAD, WHITEHOUSE, TX 75791 (NAICS 238130). OSHA activity number 344100391.
Where did this inspection happen?
- Establishment
- CHRIS CLAY CONSTRUCTION, LLC
- Site address
- 17730 SOUTH POINT ROAD
- City
- WHITEHOUSE
- State
- TX
- ZIP
- 75791
- Mailing
- 10617 HWY. 31 EAST, MURCHISON, TX 75778
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $3978.00
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard: (a) On June 20, 2019 employees at the site were exposed to a struck-by hazard when a carport had been constructed on temporary vertical supports not having the strength and structural integrity to support its weight safely.
Recent events (1)
- — Z (S) $3978
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $3978.00
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) Employees at the site were exposed to electrical shock hazards when a electrical receptacle box and non-metallic sheathed wiring listed for permanent installations was used in a temporary application.
Recent events (1)
- — Z (S) $3978
1926.405 G02 IV
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $3978.00
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) Employees at the site were exposed to electrical shock hazards when strain relief was not used on a job made junction box.
Recent events (1)
- — Z (S) $3978
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344100391.