Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DYNAMIC R FRAMING LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DYNAMIC R FRAMING LLC in LOT 3 BLOCK 25 WEST LADLE RAPIDS, MERIDIAN, ID 83642 (NAICS 238130). OSHA activity number 344112842.

Watch Dynamic R Framing LLC — free Get an email when a new federal OSHA severe-injury report for Dynamic R Framing LLC is published. One employer, no account, unsubscribe in one click.
Site address
LOT 3 BLOCK 25 WEST LADLE RAPIDS
City
MERIDIAN
State
ID
ZIP
83642
Mailing
14800 HWY 44, CALDWELL, ID 83607
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

7 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $853.00 Reduced
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:    (a)  On or about June 26, 2019, and at times prior, employees were exposed to eye hazards from flying objects while use pneumatic nail guns without approved eye protection.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $852.5
  • — Z (S) $1705

1926.451 B01

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $3410.00 · Current $1705.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii).    a)  On or about June 26, 2019, and at times prior, employees were exposed to fall hazards of 15 feet above the ground while working on a 10 inch wide scaffold plank from homemade scaffolding.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1705
  • — Z (S) $3410

1926.501 B13

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a)  On or about June 26, 2019, and at times prior, employees were exposed to fall hazards  without fall protection while working on the roof.  Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1051 A

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $853.00 Reduced
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:    a)  On or about June 26, 2019, and at times prior, employees were exposed to fall hazards when climbing wood-framed walls an additional 2.2 feet beyond the top level of the 6 foot ladder being used to access trusses to install sheathing.       Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $852.5
  • — Z (S) $1705

1926.1053 B13

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  (a)  On or about June 26, 2019, and at times prior, employees were exposed to fall hazards from stepping on top level of the 6 foot Werner ladder being used to access trusses to install sheathing.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 F07 IV

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(7)(iv): Equipment connected by cord and plug. Under any of the conditions described in paragraphs (f)(7)(iv)(A) through (f)(7)(iv)(C) of this section, exposed noncurrent-carrying metal parts of cord- and plug-connected equipment which may become energized shall be grounded.  (a) On or about June 26, 2019, and at times prior, employees were cutting sheathing using Skilsaw's that had the grounding prongs removed.  Note: Abatement certification is required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  (a) On or about June 26, 2019, and at times prior, and employee was cutting sheathing using a Makita reciprocating saw  that had a cord pulled away from the plug.   Note: Abatement certification is required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344112842.