WYOMISSING, PA —
OSHA Inspection: SFS GROUP USA, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SFS GROUP USA, INC. in 1045 SPRING STREET, WYOMISSING, PA 19610 (NAICS 332722). OSHA activity number 344116892.
Where did this inspection happen?
- Establishment
- SFS GROUP USA, INC.
- Site address
- 1045 SPRING STREET
- City
- WYOMISSING
- State
- PA
- ZIP
- 19610
- Mailing
- 1045 SPRING STREET, WYOMISSING, PA 19610
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332722
- Employees
- 600
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $13260.00 · Current $13260.00
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed; a) Amba BM-6 40107 - The employer did not ensure that the chain and sprocket was effectively guarded resulting in an employee suffering an amputation while attempting to clean the machine while it was running, on or about June 19 2019. b) Amba BM-6 40108 - The employer did not ensure that the chain and sprocket was effectively guarded exposing employees to amputation or caught-in hazards, on or about June 19 2019. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- — Z (S) $13260
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $9472.00 · Current $9472.00
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i; a) Cold Forming Department - The compressed air used for cleaning equipment including personnel was measured at 80 p.s.i., on or about June 27 2019. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $9472
More inspections in this industry (NAICS 332722)
MINNEAPOLIS, MN—2026-06-30
111503 - BOKERS INC
BURTON, MI—2026-06-12
MID-STATES BOLT & SCREW LLC
LA JUNTA, CO—2026-05-18
LEWIS BOLT AND NUT COMPANY
HOLLY, MI—2026-05-12
ACUMENT GLOBAL TECHNOLOGIES
FRASER, MI—2026-04-21
MAX MOTHES MANUFACTURING LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.