YONKERS, NY —
OSHA Inspection: CASTRO BROTHERS ROOFING & SIDING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CASTRO BROTHERS ROOFING & SIDING in HUNTER AVENUE, YONKERS, NY 10704 (NAICS 238170). OSHA activity number 344120811.
Where did this inspection happen?
- Establishment
- CASTRO BROTHERS ROOFING & SIDING
- Site address
- HUNTER AVENUE
- City
- YONKERS
- State
- NY
- ZIP
- 10704
- Mailing
- 97 BEVERLY ROAD, WHITE PLAINS, NY 10605
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $3410.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A) Exterior on the ground under the scaffold: An employee was exposed to head injuries while working below siding activities. The employee was not protected by a hard hat or protective helmet, on or about June 17th, 2019.
Recent events (2)
- — I (S) $0
- — Z (S) $3410
1926.451 G01
- Issued
- Penalty
- Initial $3978.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. A) Pump jack scaffold on the left side of the house: An employee was exposed to fall hazards of approximately 18 feet while working on a pump jack scaffold that was not protected by a complete guardrail system (including end rails) or another means of fall protection in place, on or about June 17th, 2019.
Recent events (2)
- — I (S) $2250
- — Z (S) $3978
1926.452 J02
- Issued
- Penalty
- Initial $3978.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. A) Pump jack scaffold on the left side of the house: An employee was exposed to fall hazards of approximately 18 feet while working on a pump jack scaffold that was not braced at the bottom, on or about June 17th, 2019.
Recent events (2)
- — I (S) $2250
- — Z (S) $3978
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344120811.