1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: BAUTISTA FRAMING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BAUTISTA FRAMING, LLC in CARRIAGE HILL AVE & CONVEYANCE ST, NAMPA, ID 83686 (NAICS 238130). OSHA activity number 344121488.

Watch Bautista Framing, LLC — free Get an email when a new federal OSHA severe-injury report for Bautista Framing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
CARRIAGE HILL AVE & CONVEYANCE ST
City
NAMPA
State
ID
ZIP
83686
Mailing
5114 E ROBERTS LANE, NAMPA, ID 83687
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $1800.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    (a) Workers engaged in framing and sheathing a portion of roof ("California overhang") were exposed to fall hazards up to 19 to 20 feet to the ground below.    NOTE:  Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2842

1926.1052 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $800.00 Reduced
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge:    (a)  Workers using the interior stairs to access the upper floor did not have a handrail.    NOTE:  Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1705

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3410.00 · Current $1400.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    (a)  A folded A-frame ladder was used to access the roof with only the top and top step above the roofline extending approximately 2 feet.    NOTE:  Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $3410

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed:  (a)  An A-frame ladder was used in the closed position to access the roof and not as designed in the fully open position with spreaders locked.  For this type of access, a secured extension ladder is more appropriate for the task.  NOTE:  Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View BAUTISTA FRAMING, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344121488.