Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JVN RESTORATION INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JVN RESTORATION INC. in 6500 16TH AVE, BROOKLYN, NY 11204 (NAICS 562910). OSHA activity number 344142559.

Watch JVN Restoration INC. — free Get an email when a new federal OSHA severe-injury report for JVN Restoration INC. is published. One employer, no account, unsubscribe in one click.
Site address
6500 16TH AVE
City
BROOKLYN
State
NY
ZIP
11204
Mailing
47 FOSTER ROAD, STATEN ISLAND, NY 10309
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
70
Ownership type
A

3 citations on file for this inspection.

1926.850 B

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $9282.00 · Current $0.00 Reduced
29 CFR 1926.850(b): The walls or floors were not shored or braced where employee(s) were required to work within a damaged structure to be demolished.    a) Temporary shoring/ bracing was not provided in the 4th floor to support the roof slab when the roof slab was weakened due to water damage; employees were exposed to structural collapse hazard.       Location: 6500 16th Ave, Brooklyn, NY; School I.S. 227    On or about 7/5/2019    NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9282

1926.850 A

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $9282.00 · Current $8000.00 Reduced
29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the conditions of the framing floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations.      a)  The employer did not ensure that the (flat) roof will support employees and equipment during roof repair that required removal of part of the deteriorated concrete of the roof slab; employee and the machine he was on broke through the roof and fell 15 feet to the 4th floor.      Location: 6500 16th Ave, Brooklyn, NY; School I.S. 227      On or about 7/5/2019      NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (O) $8000
  • — Z (S) $9282

1926.856 A

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $8000.00
29 CFR 1926.856(a): Floors or working surfaces were not of sufficient strength to support the imposed load of mechanical equipment:        a)  Employer was using a ride-on floor scraper machine on the concrete roof that was weakened due to water damage; employer did not determine if the roof can support the weight of the machine; employees were exposed to structural collapse hazard.         Location: 6500 16th Ave, Brooklyn, NY; School I.S. 227      On or about 7/5/2019      NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (O) $8000
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344142559.