Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHENGHAI XUE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHENGHAI XUE in 2011 61ST STREET, BROOKLYN, NY 11204 (NAICS 236118). OSHA activity number 344144035.

Watch Chenghai XUE — free Get an email when a new federal OSHA severe-injury report for Chenghai XUE is published. One employer, no account, unsubscribe in one click.
Establishment
CHENGHAI XUE
Site address
2011 61ST STREET
City
BROOKLYN
State
NY
ZIP
11204
Mailing
2011 61ST STREET, BROOKLYN, NY 11204
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

10 citations on file for this inspection.

1926.95 A

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $1705.00
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided.    Location: a) At 2011 61st Street, Brooklyn, NY 11204    On or about 07/10/2019, employees were working in the jobsite without personal protective equipment for foot, and were exposed to struck by or puncture hazards.
Recent events (1)
  • — Z (S) $1705

1926.300 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use.    Location:  a) On the first floor level of the jobsite:                                                     On or about 7/10/2019, employee used a portable hand grinder without a guard to cut floor tiles.
Recent events (1)
  • — Z (S) $2842

1926.304 I01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1926.304(i)(1): Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut.    Location:  a) On the first floor level of the jobsite:    On or about 07/10/2019, employees used a circular hand-fed ripsaw without an anti-kickback guard. The employee was exposed to struck by hazard.
Recent events (1)
  • — Z (S) $2842

1926.403 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.     Location:  a) On basement floor level of the jobsite:                                  On or about 07/10/2019, employees used a power strip to energize electrical equipment. The power tap was not listed to be use in a construction work environment.
Recent events (1)
  • — Z (S) $2273

1926.404 F06

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous      Location:  a) On basement floor level of the jobsite:     On or about 07/10/2019, employees used a power strip to energize electrical equipment. The path to ground was not continuous because the ground pin of the cord was missing.
Recent events (1)
  • — Z (S) $0

1926.403 I02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.    Location:  a) On basement floor level of the jobsite:    On or about 07/10/2019, an electrical panel with electrical live parts and wirings exposed that was not covered. Employees were exposed to electric shock hazard.    b) On basement floor level of the jobsite:    On or about 07/10/2019, electrical meters with electrical live parts and wirings exposed that were covered with cardboards. The cardboards were not adequate covers. Employees were exposed to electric shock hazard.
Recent events (1)
  • — Z (S) $2842

1926.405 A02 II E

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage.     Location:  a) On basement floor level of the jobsite:     On or about 07/10/2019, lamps used in temporary wiring for general illumination in the jobsite that were not protected from accidental contact or breakage. Employees were exposed to electric shock hazard.
Recent events (1)
  • — Z (S) $2273

1926.405 J01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported.     Location:  a) On basement floor level of the jobsite:     On or about 07/10/2019, an electrical junction box with receptacles was not securely supported, and was used to energize electrical equipment.
Recent events (1)
  • — Z (S) $2273

1926.501 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    Location:  a) On the first floor level of the jobsite:    On or about 07/10/2019, employees were installing floor tiles and were exposed to falling approximately 8 feet to the lower level. Employees were not protected by the use of guardrails, safety nets, or personal fall arrest systems.
Recent events (1)
  • — Z (S) $3978

1926.1053 B16

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.    Location:  a)  On basement floor level of the jobsite:    On or about 07/10/2019, a portable ladder with broken rear rail was not marked as defective and was not withdrawn from service. Employees used the defective ladder to install ceiling drywall and were exposed to fall hazard.