Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DURABLE GOOD-MEN JV LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DURABLE GOOD-MEN JV LLC in BUILDING 74 NAVAL BASE SAN DIEGO, SAN DIEGO, CA 92136 (NAICS 238160). OSHA activity number 344147483.

Watch Durable Good-Men JV LLC — free Get an email when a new federal OSHA severe-injury report for Durable Good-Men JV LLC is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 74 NAVAL BASE SAN DIEGO
City
SAN DIEGO
State
CA
ZIP
92136
Mailing
3940 HANCOCK STREET SUITE 212, SAN DIEGO, CA 92110
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.501 B10

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $5636.00 · Current $5636.00
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    B74 Roof: Employees were performing roofing activities, such as installing ply and air welding seams, on a roof 51 feet in width. Employees were using warning lines erected at least 6 feet from the edge without the use of a safety monitoring system. Employees were exposed to 24-foot fall hazards to the lower level.
Recent events (2)
  • — I (O) $5636
  • — Z (S) $5636

1926.502 F02 I

Other-than-serious 3 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(f)(2)(i): The rope, wire, or chain was not flagged at not more than 6-foot (1.8 m) intervals with high-visibility material:    B74 Roof: Employees were performing roofing activities, such as installing ply and air welding seams on the roof. In the following locations, the distance between flags exceeded 6 feet:  a) North edge of roof: The distance between flags measured 92 inches  b) South edge of roof: The distance between flags measured 118 inches  c) West edge of roof: The distance between flags measured 137 inches  Employees were exposed to 24-foot fall hazards to the lower level.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 F02 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface.    B74 Roof North End: Employees were performing roofing activities, such as installing ply and air welding seams, on a roof 51 feet in width. Employees were using warning lines as the means of fall protection. The height of the warning line measured 27 inches above the roof surface. Employees were exposed to 24-foot fall hazards to the lower level.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.1051 A

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $5636.00 · Current $5636.00
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided:    B74 Roof: Employees were performing roofing activities, such as installing ply and air welding seams. In the following locations, employees accessed levels of the roof that had changes in elevation greater than 19 inches:  a) When accessing the roof from the fixed ladder, the change in elevation was 24 inches.
Recent events (2)
  • — I (O) $5636
  • — Z (S) $5636

View DURABLE GOOD-MEN JV LLC's full OSHA safety record →