Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JAIME GODINEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAIME GODINEZ in 1616 N. TOWN EAST BLVD, MESQUITE, TX 75150 (NAICS 238160). OSHA activity number 344147558.

Watch Jaime Godinez — free Get an email when a new federal OSHA severe-injury report for Jaime Godinez is published. One employer, no account, unsubscribe in one click.
Establishment
JAIME GODINEZ
Site address
1616 N. TOWN EAST BLVD
City
MESQUITE
State
TX
ZIP
75150
Mailing
4622 OLD BLUE CIR, FORT WORTH, TX 76111
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, the employer did not ensure that each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.  This violation occurred on July 2, 2019, where at least six (6) employees working on roof without fall protection and exposed to falls of more than 20 feet to the concrete below.
Recent events (1)
  • — Z (S) $3978

1926.1053 B01

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  This violation occurred on July 2, 2019, where at least 6 employees used the extension ladder to access the upper landing and were exposed to falls of more than 20 feet to the concrete below.
Recent events (1)
  • — Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344147558.